Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SKANA ALUMINUM COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SKANA ALUMINUM COMPANY in 2009 MIRRO DR., MANITOWOC, WI 54220 (NAICS 331315). OSHA activity number 346918055.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Skana Aluminum Company — free Get an email when a new federal OSHA severe-injury report for Skana Aluminum Company is published. One employer, no account, unsubscribe in one click.
Site address
2009 MIRRO DR.
City
MANITOWOC
State
WI
ZIP
54220
Mailing
PO BOX 1477 2009 MIRRO DRIVE, MANITOWOC, WI 54221
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331315
Employees
170
Ownership type
A

4 citations on file for this inspection.

1910.28 B06 I

Serious Gravity 5 3 instances 4 exposed
Issued
Jan 30, 2024
Abate by
Feb 28, 2024
Penalty
Initial $9,521 · Current $4,760 Reduced
29 CFR 1910.28(b)(6)(i): Each employee less than 4 feet (1.2 m) above dangerous equipment is protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system, unless the equipment is covered or guarded to eliminate the hazard.  (a)  On or about August 17, in the Cold Mill Area, on the outfeed side of the Lowery where coils are removed from the conveyor system, opening at the end next to the main aisle was not guarded exposing employees to fall hazards and caught between for the conveying system.  (b)  On or about August 17, in the Cold Mill Area, on the outfeed side of the Lowery by the operator's station, openings by the first coil car and moving conveyor exposed employees to fall hazards and moving conveying systems.  (c)  On or about August 17, in the Cold Mill Area, on the infeed side of the Lowery, next to the shear, the guardrail system was not maintained in the closed position exposing employees to fall hazards and moving conveying systems.
Recent events (2)
  • — I (S) $4760
  • — Z (S) $9521

1910.147 C04 II

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2024
Abate by
Mar 6, 2024
Penalty
Initial $13,066 · Current $6,533 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:  On or about August 8, 2023, at an establishment located at 2009 Mirro Drive, Manitowoc, Wisconsin, in the Skana Aluminum Products Area, the Lockout-Tagout Procedure for the Automated Circle Shear did not cover the set-up activities and the safe means and methods to be utilized when employees entered the cell area exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $6533
  • — Z (S) $13066

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 30, 2024
Abate by
Feb 28, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about August 8, 2023, employees were exposed to machine hazards associated with moving parts when they engaged in set-up activities on the Lucas Circular Shear in the Skana Aluminum Products Area.  The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to set-up.  The machine was not deenergized prior to the employee engaging in the servicing / maintenance activity.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 30, 2024
Abate by
Feb 28, 2024
Penalty
Initial $7,934 · Current $3,967 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  On or about August 17, 2023, at an establishment located at 2009 Mirro Drive, Manitowoc, Wisconsin, in the Cold Mill Department, the Loewy-Hydropress shear was not guarded on the backside when employees were removing cut scraps and holding the coil sheet for sample exposing employees to caught between hazards.
Recent events (2)
  • — I (S) $3967
  • — Z (S) $7934

View Skana Aluminum Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346918055.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.