BROOKLYN, NY —
OSHA Inspection: ALDO'S MASONRY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALDO'S MASONRY INC. in 7621 12TH AVENUE, BROOKLYN, NY 11228 (NAICS 238140). OSHA activity number 346918840.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALDO'S MASONRY INC.
- Site address
- 7621 12TH AVENUE
- City
- BROOKLYN
- State
- NY
- ZIP
- 11228
- Mailing
- 94 ESCANABA AVENUE, STATEN ISLAND, NY 10308
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Jan 23, 2024
- Penalty
- Initial $4,839 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1):Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports. Location: Worksite; front facing fa�ade of residence. a) On or about 08/18/2023, employees worked on a 2-tier tubular welded frame scaffold that was not fully planked or decked between the front uprights and the guardrail supports.
Recent events (3)
- — F (S) $2000
- — C (S) $4839
- — Z (S) $4839
1926.451 E01
- Issued
- Jan 23, 2024
- Penalty
- Initial $4,839 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces shall not be used as a means of access. Location: Worksite; front facing fa�ade of residence. a) On or about 08/18/2023, employees working from a 2-tier high tubular welded frame scaffold that did not have a safe means of access. Employees climbed the frames and cross braces to access the working platforms.
Recent events (3)
- — F (S) $2000
- — C (S) $4839
- — Z (S) $4839
1926.451 G01 VII
- Issued
- Jan 23, 2024
- Penalty
- Initial $4,839 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: Worksite; front facing fa�ade of residence. a) On or about 08/18/2023, employees worked on a 2-tier high tubular welded frame scaffold and the scaffold was not equipped for guardrails.
Recent events (3)
- — F (S) $1000
- — C (S) $4839
- — Z (S) $4839
More inspections in this industry (NAICS 238140)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346918840.