Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STEPHEN M DANIELS ELECTRICAL CONTRACTORS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STEPHEN M DANIELS ELECTRICAL CONTRACTORS in 61 RANCK AVENUE, LANCASTER, PA 17601 (NAICS 238210). OSHA activity number 346920309.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stephen M Daniels Electrical Contractors — free Get an email when a new federal OSHA severe-injury report for Stephen M Daniels Electrical Contractors is published. One employer, no account, unsubscribe in one click.
Site address
61 RANCK AVENUE
City
LANCASTER
State
PA
ZIP
17601
Mailing
1750 COLUMBIA AVENUE, LANCASTER, PA 17603
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
22
Ownership type
A

4 citations on file for this inspection.

1910.269 A02 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 9, 2024
Abate by
Feb 12, 2024
Penalty
Initial $6,250 · Current $6,500
29 CFR  1910.269(a)(2)(i)(A):Each employee was not trained in, and familiar with, the safety-related work practices, safety procedures, and other safety requirements in this section that pertain to his or her job assignments.  a) 61 Ranck Avenue, Lancaster Pennsylvania - Customer Residence, - Employees performed electrical servicing and maintenance activities on live-wire connections from power distribution lines.  The employer did not develop and implement Electrical Safe Work Practices, energy control procedures, employee training, and periodic audits exposing employees to electrical shock, electrical burns, arc burns, and thermal contact burns hazards on or about July 10, 2023.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $6250

1910.269 A02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 9, 2024
Abate by
Feb 12, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.269(a)(2)(iv): The employer did not determine that each employee was complying with all required safety-related work practices required by this section by regular supervision and annual inspections:  a) 61 Ranck Avenue, Lancaster Pennsylvania - Customer Residence, - Employees performed electrical servicing and maintenance activities on live-wire connections from power distribution lines.  Regular supervision and annual inspections of Electrical Safe Work Practices, energy control procedures, employee training, and periodic audits were not conducted, on or about July 10, 2023.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.269 C01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 9, 2024
Abate by
Feb 12, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.269(c)(1)(ii): The employer did not ensure that the employee in charge conducted a job briefing that met paragraphs (c)(2), (c)(3), and (c)(4) of 29 CFR 1910.269 with the employees as required.   a) 61 Ranck Avenue, Lancaster Pennsylvania - Customer Residence, - Employees performed electrical servicing and maintenance activities on live-wire connections from power distribution lines.  Prior to the start of work job briefing were not conduced to inform employee of the hazards of the job, special precautions, personal protective equipment, work to be performed, or about July 10, 2023.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.138 A

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 9, 2024
Abate by
Feb 27, 2024
Penalty
Initial $6,250 · Current $0 Reduced
29 CFR  1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees hands were exposed to hazardous condition(s).  a) 61 Ranck Avenue, Lancaster Pennsylvania - Customer Residence, - Employees performed electrical servicing and maintenance activities on live-wire connections from power distribution lines.  The use of proper personal equipment was not enforced on or about July 10, 2023.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6250

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346920309.