OSHA Inspection: CHAMPION HOME BUILDERS, INC.

Unprogrammed Other inspection · Health discipline

On , OSHA opened an unprogrammed Other health inspection of CHAMPION HOME BUILDERS, INC. in 6420 WEST ALLISON ROAD, CHANDLER, AZ 85226 (NAICS 332311). OSHA activity number 346920382.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Champion Home Builders, INC. — free Get an email when a new federal OSHA severe-injury report for Champion Home Builders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6420 WEST ALLISON ROAD
City
CHANDLER
State
AZ
ZIP
85226
Mailing
6420 WEST ALLISON ROAD, CHANDLER, AZ 85226
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
221
Ownership type
A

6 citations on file for this inspection.

1910.132 D01 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Sep 28, 2023
Abate by
Oct 11, 2023
Penalty
Initial $14,733 · Current $7,500 Reduced
29 CFR  1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment:  a) Walls:  An employee working with corrosive Voramer MB 3099 adhesive was not wearing appropriate personal protective equipment, exposing that employee to eye damage and breathing hazards from the chemical spray.
Recent events (2)
  • — I (O) $7500
  • — Z (S) $14733

1910.253 B02 II

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Sep 28, 2023
Abate by
Oct 11, 2023
Penalty
Initial $14,733 · Current $7,500 Reduced
29 CFR  1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:   (a)	Frames:  Multiple compressed gas cylinders were not secured to ensure that the cylinders would not be knocked over, exposing employees to injuries from projectiles.
Recent events (2)
  • — I (O) $7500
  • — Z (S) $14733

1910.253 B02 IV

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Sep 28, 2023
Abate by
Oct 11, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  (a)	Frames:  Multiple unsecured compressed gas cylinders did not have valve protection caps, exposing employees to injury from projectiles.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 3 instances 30 exposed
Issued
Sep 28, 2023
Penalty
Initial $12,278 · Current $9,000 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)	Interior Walls - A power tool was plugged to a series of connected extension cords, exposing employees to electrical and fire hazards. b)	Interior Walls - A receptacle box, designed for permanent mounting, provided with a flexible cord, was used as an extension cord to power a Power Breezer cooling system, exposing employees to electrical and fire hazards. c)	Catwalk- A receptacle box, designed for permanent mounting, was used as an extension cord to provide power to a DeWalt saw, exposing employees to electrical and fire hazards.
Recent events (2)
  • — I (S) $9000
  • — Z (S) $12278

1910.334 A02 I

Serious Gravity 5 2 instances 1 exposed
Issued
Sep 28, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a) Interior Walls - The employer did not ensure that the flexible cord to the router power tool was visually inspected before use for external defects. The outer insulation jacket to the flexible cord was damaged with exposed internal wires, exposing employees to electrical hazards. b) Interior Walls - The employer did not ensure that the extension cord supplying power to the router power tool was visually inspected before use for external defects. The outer insulation jacket to the extension cord was damaged with exposed internal wires, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F06 II

Other-than-serious 1 instance 3 exposed
Issued
Sep 28, 2023
Abate by
Oct 11, 2023
Penalty
Initial $1,378 · Current $500 Reduced
29 CFR  1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  a) Maintenance Shop- multiple containers were not labeled to indicate the contents or hazards, exposing employees to hazards from contact with unknown chemicals.
Recent events (2)
  • — I (O) $500
  • — Z (O) $1378