Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INDUSTRIAL POWER SYSTEMS, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of INDUSTRIAL POWER SYSTEMS, INC in 129 DIXIE HIGHWAY, ROSSFORD, OH 43460 (NAICS 238220). OSHA activity number 346924731.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Industrial Power Systems, INC — free Get an email when a new federal OSHA severe-injury report for Industrial Power Systems, INC is published. One employer, no account, unsubscribe in one click.
Site address
129 DIXIE HIGHWAY
City
ROSSFORD
State
OH
ZIP
43460
Mailing
146 DIXIE HIGHWAY, ROSSFORD, OH 43460
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
400
Ownership type
A

2 citations on file for this inspection.

1910.178 A04

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 26, 2023
Penalty
Initial $15,625 · Current $7,813 Reduced
29 CFR  1910.178(a)(4):Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:  a)	Industrial Power System, Inc. On or about August 22, 2023 at the address of 129 Dixie Highway Rossford, OH 43460. The employer did not seek or ensure manufacture's approval for modifications to the Yale Lift Truck's (model: ERC060GHN36TF094 ) fork(s), such as a fabricated hole near the fork tip prior to use. Employee(s) utilizing the Yale Lift Truck in this condition to handle tools and equipment, without the benefit of the manufacture's evaluation and approval were exposed to hazards associated with load loss and displacement.
Recent events (2)
  • — I (S) $7813
  • — Z (S) $15625

1910.178 O05

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 26, 2023
Penalty
Initial $0 · Current $0
1910.178(o)(5)  A load engaging means shall be placed under the load as far as possible; the mast shall be carefully tilted backward to stabilize the load.  29 CFR  1910.178(o)(1): Load(s) on powered industrial truck(s) were not stable or safely arranged:  a)	Industrial Power System, Inc. On or about August 22, 2023 at the address of 129 Dixie Highway Rossford, OH 43460. The employer did not ensure that only stable or safely arranged loads were handled. Employee(s) utilizing the Yale Lift Truck (model: ERC060GHN36TF094) to hoist tools and equipment by way of "free rigging" (placing unsecured rigging on the fork(s), for a below-the-fork material handling) were exposed to hazards associated with load displacement and loss of stability.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Industrial Power Systems, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346924731.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.