Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GOLDEN GATE CONSTRUCTION, INC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of GOLDEN GATE CONSTRUCTION, INC in 2151 STATE ROAD, LANCASTER, PA 17601 (NAICS 236115). OSHA activity number 346924970.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Golden Gate Construction, INC — free Get an email when a new federal OSHA severe-injury report for Golden Gate Construction, INC is published. One employer, no account, unsubscribe in one click.
Site address
2151 STATE ROAD
City
LANCASTER
State
PA
ZIP
17601
Mailing
6440 TEWSBURY DRIVE, KNOXVILLE, TN 37921
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236115
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.451 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 7, 2024
Abate by
Mar 5, 2024
Penalty
Initial $4,839 · Current $3,000 Reduced
29 CFR  1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement:   a) 2151 State Road, Lancaster, PA -  An employee worked on a fabricated frame scaffold, with missing bracing on the working side, exposing employees to collapse and fall hazards, on or about August 18, 2023.  b) 2151 State Road, Lancaster, PA -  An employee worked on a fabricated frame scaffold, with red duct to secure the cross bracing and uprights, exposing employees to collapse and fall hazards, on or about August 18, 2023  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4839

1926.451 G04 III

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 7, 2024
Abate by
Mar 5, 2024
Penalty
Initial $4,839 · Current $3,000 Reduced
29 CFR  1926.451(g)(4)(iii): When midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent structural members are used, they were not installed between the top edge of the guardrail system and the scaffold platform.   a) 2151 State Road, Lancaster, PA -  An employee worked 13 feet 7 inches above grade on a fabricated frame scaffold, with missing mid-rails, exposing employees to a fall hazards, on or about August 18, 2023.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4839

1926.451 G04 VII

Other-than-serious 1 instance 1 exposed
Issued
Feb 7, 2024
Abate by
Mar 5, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(4)(vii): Each toprail or equivalent member of a guardrail system was not capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along its top edge of at least 100 pounds (445 n) or guardrail systems installed on single-point adjustable suspension scaffolds or two-point adjustable suspension scaffolds, and at least 200 pounds (890 n) for guardrail systems installed on all other scaffolds.   a) 2151 State Road, Lancaster, PA -  An employee worked on a fabricated frame scaffold, red duct tape was used to secure the guardrail , on or about August 18, 2023.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Golden Gate Construction, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346924970.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.