OCALA, FL —
OSHA Inspection: ANODIZE, INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ANODIZE, INC in 5817 NW 44TH AVENUE, OCALA, FL 34482 (NAICS 332813). OSHA activity number 346926868.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANODIZE, INC
- Site address
- 5817 NW 44TH AVENUE
- City
- OCALA
- State
- FL
- ZIP
- 34482
- Mailing
- 5817 NW 44TH AVENUE, OCALA, FL 34482
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 32
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.22 A01
- Issued
- Nov 24, 2023
- Abate by
- Jan 12, 2024
- Penalty
- Initial $6,250 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): 29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. a) At 5817 NW 44TH Avenue, Ocala, Florida; On or about August 22, 2023, the employer did not ensure that the floor was free of obstructions such as extension cords, exposing employees to a trip and fall hazard.
Recent events (2)
- — I (S) $3750
- — Z (S) $6250
1910.22 A02
- Issued
- Nov 24, 2023
- Abate by
- Jan 12, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): The employer did not ensure that the floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided: a) At 5817 NW 44TH Avenue, Ocala, Florida; On or about August 22, 2023, the employer did not ensure that the walking working surfaces were kept dry, in that, rinse water and dip tank liquid from the process spills onto the floor resulting in wet and slippery surfaces.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Nov 24, 2023
- Abate by
- Jan 12, 2024
- Penalty
- Initial $6,250 · Current $3,750 Reduced
0689
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) At 5817 NW 44TH Avenue, Ocala, Florida; On or about August 22, 2023, the employer did not develop and implement a written worksite specific respiratory protection program for employees provided and required to use tight-fitting facepiece respirators during anodizing activities on auto parts.
Recent events (2)
- — I (S) $3750
- — Z (S) $6250
1910.134 E01
- Issued
- Nov 24, 2023
- Abate by
- Jan 12, 2024
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) At 5817 NW 44TH Avenue, Ocala, Florida; On or about August 22, 2023, the employer did not ensure that employees required to wear tight-fitting respirators were provided a medical evaluation to determine their ability to use respirators in the workplace. Employees involved in anodizing activities were provided and required to wear 3M -Half Face and Full-Face Respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Nov 24, 2023
- Abate by
- Jan 12, 2024
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.134(f)(2):Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator. a) At 5817 NW 44TH Avenue, Ocala, Florida; On or about August 22, 2023, the employer did not ensure that employees required to wear tight-fitting respirator were fit tested prior to initial use of the respirator in the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K
- Issued
- Nov 24, 2023
- Abate by
- Jan 12, 2024
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.134(k):The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: a) At 5817 NW 44TH Avenue, Ocala, Florida; On or about August 22, 2023, employer did not ensure that employees who utilized respirators, were trained prior to wearing respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Nov 24, 2023
- Penalty
- Initial $6,250 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) At 5817 NW 44TH Avenue, Ocala, Florida; On or about August 22, 2023, in the tank room, two junction boxes had a missing cover, exposing employees to electrical shock and fire hazards.
Recent events (2)
- — I (S) $3750
- — Z (S) $6250
1910.305 J01 I
- Issued
- Nov 24, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lamp holders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact: a) At 5817 NW 44TH Avenue, Ocala, Florida; On or about August 22, 2023, a receptacle located between tank 11 (red tanks) and the adjacent tank, had a separated cover and detached form the wall mount, exposing employees to electrical shock and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Anodize, INC
View Anodize, INC's full OSHA safety record →
More inspections in this industry (NAICS 332813)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346926868.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.