CIBOLO, TX —
OSHA Inspection: AXTON, LLC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AXTON, LLC. in 109 CIBOLO DRIVE, CIBOLO, TX 78108 (NAICS 336212). OSHA activity number 346935570.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AXTON, LLC.
- Site address
- 109 CIBOLO DRIVE
- City
- CIBOLO
- State
- TX
- ZIP
- 78108
- Mailing
- 109 CIBOLO DRIVE, CIBOLO, TX 78108
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336212
- Employees
- 20
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.107 B05 I
- Issued
- Sep 8, 2023
- Abate by
- Oct 4, 2023
- Penalty
- Initial $4,687 · Current $2,109 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained. On or about August 23, 2023, and at times prior thereto, no visible gauges or manometers were installed on the spray booth, exposing employees to chemical hazards.
Recent events (2)
- — I (O) $2109.15
- — Z (S) $4687
1910.107 B05 IV
- Issued
- Sep 8, 2023
- Abate by
- Oct 4, 2023
- Penalty
- Initial $4,687 · Current $2,109 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers. On or about August 23, 2023, and at times prior thereto, the spray booth did not have automatic sprinklers installed, exposing employees to flammable and combustible hazards.
Recent events (2)
- — I (S) $2109.15
- — Z (S) $4687
1910.107 B09
- Issued
- Sep 8, 2023
- Penalty
- Initial $4,687 · Current $2,109 Reduced
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction. On or about August 23, 2023, and at times prior thereto, products used in spray operations were kept directly adjacent to the spray booth within 3 feet, preventing accessibility for cleaning, and exposing employees to fire and combustible hazards.
Recent events (2)
- — I (O) $2109.15
- — Z (S) $4687
1910.107 G07
- Issued
- Sep 8, 2023
- Penalty
- Initial $4,687 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(g)(7): "NO SMOKING" sign(s) in large letters on contrasting color backgrounds were not conspicuously posted at spraying area(s) and paint storage room(s). On or about August 23, 2023, and at times prior thereto, spraying areas did not have "No Smoking" signs posted, exposing employees to flammable and combustible hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $4687
1910.110 F06 II
- Issued
- Sep 8, 2023
- Abate by
- Oct 4, 2023
- Penalty
- Initial $4,687 · Current $2,109 Reduced
General-duty citation text
29 CFR 1910.110(f)(6)(ii): Containers were not stored in a suitable enclosure or otherwise protected against tampering. On or about August 23, 2023, and at times prior thereto, a propane cannister was kept outside the propane cage at the facility, exposing employees to fire hazards as a result of the container not being protected from tampering.
Recent events (2)
- — I (O) $2109.15
- — Z (S) $4687
1910.134 C01
- Issued
- Sep 8, 2023
- Abate by
- Oct 4, 2023
- Penalty
- Initial $4,687 · Current $2,109 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about August 23, 2023 and at times prior thereto, the employer had not developed a written respiratory program that included provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures, such as procedures for selecting respirator for use, medical evaluations, fit testing procedures, procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding, and otherwise maintaining respirators, and training of employees in respiratory hazards, exposing employees to various respiratory hazards.
Recent events (2)
- — I (O) $2109.15
- — Z (S) $4687
1910.151 C
- Issued
- Sep 8, 2023
- Penalty
- Initial $3,984 · Current $1,793 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use. On or about August 23, 2023, and at times prior thereto, employees were exposed to corrosive paint thinner during the process of daily operations without suitable facilities for quick drenching of the eyes or body for immediate emergency use, exposing the employees to chemical hazards.
Recent events (2)
- — I (O) $1792.8
- — Z (S) $3984
1910.178 L06
- Issued
- Sep 8, 2023
- Abate by
- Oct 4, 2023
- Penalty
- Initial $7,813 · Current $3,516 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): On or about August 23, 2023, and at times prior thereto, employees operated forklifts within the facility without having been trained and evaluated, exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $3515.85
- — Z (S) $7813
1910.253 B04 III
- Issued
- Sep 8, 2023
- Penalty
- Initial $4,687 · Current $2,109 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. On or about August 23, 2023, and at times prior thereto, oxygen cylinders were stored directly adjacent to acetylene fuel gas cylinders, exposing employees to fire and combustible hazards.
Recent events (2)
- — I (O) $2109.15
- — Z (S) $4687
1910.305 G02 III
- Issued
- Sep 8, 2023
- Penalty
- Initial $4,687 · Current $2,109 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about August 23, 2023, and at times prior thereto, the flexible cord to the spray booth spraying equipment was not connected such that tension would not be transmitted to joints or terminal screws, exposing employees to electrical and fire hazards.
Recent events (2)
- — I (O) $2109.15
- — Z (S) $4687
1910.1200 E01
- Issued
- Sep 8, 2023
- Abate by
- Oct 4, 2023
- Penalty
- Initial $4,687 · Current $2,109 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met. On or about August 23, 2023, and at times prior thereto, the employer had not developed a written hazard communication program to include such items as, labels and other forms of warning, safety data sheets, and employee information and training, exposing employees to chemical hazards.
Recent events (2)
- — I (O) $2109.15
- — Z (S) $4687
1904.29 A
- Issued
- Sep 8, 2023
- Abate by
- Oct 4, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent. On or about August 23, 2023, and at times prior thereto, the employer had not utilized any OSHA Form or equivalent to keep records for employee injuries or illnesses.