On , OSHA opened a complaint safety inspection of WHITE OAK DISPLAY AND DESIGN, L.P. in 400 EAST SPRUCE STREET, PALMYRA, PA 17078 (NAICS 423990). OSHA activity number 346947930.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WHITE OAK DISPLAY AND DESIGN, L.P.
- Site address
- 400 EAST SPRUCE STREET
- City
- PALMYRA
- State
- PA
- ZIP
- 17078
- Mailing
- 400 EAST SPRUCE STREET, PALMYRA, PA 17078
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423990
- Employees
- 34
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.36 D01
- Issued
- Feb 22, 2024
- Abate by
- Mar 12, 2024
- Penalty
- Initial $4,839 · Current $0 Reduced
General-duty citation text
29 CFR 1910.36(d)(1):Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: (a) 400 E Spruce Street, Palmyra, PA; production floor emergency exit doors - On or about August 30, 2023 multiple emergency exit doors from the production floor were secured during the workday by means of a U-shaped bar dropped into two eye-bolts. Employees need special knowledge to remove the U-shaped bar prior to opening the door in the event of an emergency evacuation. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $4839
1910.147 C06 I B
- Issued
- Feb 22, 2024
- Abate by
- Mar 12, 2024
- Penalty
- Initial $6,453 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(B): The periodic inspection of the energy control procedure was not conducted to correct any deviations or inadequacies identified: (a) Production floor, Scheer Panel Saw - On or about August 30, 2023 saw blade(s) were cleaned with 117psi air hose. Periodic inspections of the energy control procedure were not conducted to identify the rotating hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $6453
1910.213 D01
- Issued
- Feb 22, 2024
- Abate by
- Mar 12, 2024
- Penalty
- Initial $8,067 · Current $12,400
General-duty citation text
29 CFR 1910.213(d)(1):Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: (a) Production floor, Powermatic table saw - On or about August 30, 2023, the table saw was not equipped with an automatically adjusting hood which would guard employees from contact with the saw blade. (b) Production floor, Delta Unisaw 10" Tilting Arbor table saw - On or about August 30, 2023, the table saw was not equipped with an automatically adjusting hood which would guard employees from contact with the saw blade. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $12400
- — Z (S) $8067
1910.213 H01
- Issued
- Feb 22, 2024
- Abate by
- Mar 12, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(1):The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material: (a) Delta Model 10 Deluxe Radial Arm Saw #5 at column 23 - On or about August 30, 2023 the lower portion of the radial saw blade was not guarded, which exposed employees to contact with the blade. (b) Delta radial saw #7 at column 23 - On or about August 30, 2023 the lower portion of the radial saw blade was not guarded, which exposed employees to contact with the blade. (c) Ridgid radial saw at column 31 - On or about August 30, 2023 the lower portion of the radial saw blade was not guarded, which exposed employees to contact with the blade. (d) Craftsman radial saw #3 - On or about August 30, 2023 the lower portion of the radial saw blade was not guarded, which exposed employees to contact with the blade. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Feb 22, 2024
- Abate by
- Mar 12, 2024
- Penalty
- Initial $4,839 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Production floor, breaker panel at Delta radial saw on column 23 - On or about August 30, 2023 sufficient access and working space was not provided and maintained at the breaker panel. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $4839
More inspections at White OAK Display and Design, L.P.
View White OAK Display and Design, L.P.'s full OSHA safety record →
More inspections in this industry (NAICS 423990)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346947930.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.