Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U-HAUL INTERNATIONAL INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of U-HAUL INTERNATIONAL INC in 169 ONTARIO STREET, COHOES, NY 12047 (NAICS 493110). OSHA activity number 346948474.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U-Haul International INC — free Get an email when a new federal OSHA severe-injury report for U-Haul International INC is published. One employer, no account, unsubscribe in one click.
Site address
169 ONTARIO STREET
City
COHOES
State
NY
ZIP
12047
Mailing
2727 N CENTRAL AVE,, PHOENIX, AZ 85004
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
10
Ownership type
A

2 citations on file for this inspection.

1910.305 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 5, 2024
Abate by
Jan 18, 2024
Penalty
Initial $8,929 · Current $8,929
29 CFR  1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:  (a) Establishment, self storage area - On or about August  31, 2023, Employees was operating an EGA EZY climb step ladder to access the top self storages units. The employees were exposed to electrical hazards at the ceiling level electrical box by moving the ladder around to storage unit.
Recent events (1)
  • — Z (S) $8929

1910.305 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 5, 2024
Abate by
Jan 18, 2024
Penalty
Initial $8,929 · Current $8,929
29 CFR  1910.305(b)(2)(i): Covers of outlet boxes having holes through which flexible cord pendants passed were not provided with bushings designed for the purpose nor did the holes have smooth, well-rounded surfaces on which the cords could bear.  (a) Establishment, self storage area - On or about August  31, 2023, Employees was operating an EGA EZY metal climb step ladder to access the top self storages units. The employees were exposed to electrical hazards at the ceiling level electrical box by moving the ladder around to storage unit.
Recent events (1)
  • — Z (S) $8929

View U-Haul International INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346948474.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.