DOUGLASSVILLE, PA —
OSHA Inspection: TECHO-BLOC CORP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TECHO-BLOC CORP in 23 QUARRY ROAD, DOUGLASSVILLE, PA 19518 (NAICS 444190). OSHA activity number 346949514.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TECHO-BLOC CORP
- Site address
- 23 QUARRY ROAD
- City
- DOUGLASSVILLE
- State
- PA
- ZIP
- 19518
- Mailing
- 23 QUARRY ROAD, DOUGLASSVILLE, PA 19518
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444190
- Employees
- 60
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jan 22, 2024
- Abate by
- Feb 15, 2024
- Penalty
- Initial $15,970 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Plate Shifter - The employer permits employees to perform servicing and maintenance on the plate shifter, such as end-of-shift cleanup, without utilizing the employer's energy control procedure, on or about August 31, 2023. b) Plate Shifter - Employees perform troubleshooting on the plate shifter, such as lubricating parts and/or clearing jams, and the employer did not ensure that energy control procedures were developed, documented and utilized to control electrical and hydraulic energy sources, on or about August 24, 2023. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $15970
1910.147 C04 II
- Issued
- Jan 22, 2024
- Abate by
- Apr 30, 2024
- Penalty
- Initial $0 · Current $15,000
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items (a) through (d) of this section: a) Plate Shifter - The employer's energy control procedure titled, "Lockout Tagout Procedure - Buffer / Cross Transport, Lockout Procedure # L/O - 0029", for performing service and maintenance on the plate shifter did not include the purpose, authorization, and means to enforce compliance, on or about August 31, 2023. b) Plate Shifter - The employer's energy control procedure titled, "Lockout Tagout Procedure - Buffer / Cross Transport, Lockout Procedure # L/O - 0029", for performing service and maintenance on the plate shifter did not include the magnitude of the electrical and hydraulic hazardous energy, on or about August 31, 2023. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $15000
- — Z (S) $0
1910.147 C07 I A
- Issued
- Jan 22, 2024
- Abate by
- Feb 26, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a) Plate Shifter - The employer did not ensure employees engaging in servicing and/or maintenance on the plate shifter, such as but not limited to, end of day cleanup, troubleshooting, lubrication, and clearing jams, received training at the authorized level that included the types and magnitude of energy sources in the workplace, and the methods and means necessary for energy isolation and control, on or about August 31, 2023. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D03
- Issued
- Jan 22, 2024
- Abate by
- Apr 30, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): b) Plate Shifter - Employees performed troubleshooting and lubricating a part on the plate shifter and did not isolate the electrical and hydraulic hazardous energy sources, on or about August 24, 2023. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jan 22, 2024
- Penalty
- Initial $9,126 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Machine Room and Plate Shifter Area - The Masa block press and the plate shifter were each protected by zoned perimeter fencing and interlocked gates. An opening in a wall separating these machines was large enough for a person to pass through, which could bypass the safeguarding of each space, on or about August 24, 2023. No abatement certification or documentation required. Techo-Bloc Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number1587314, citation number 1, item number 3, and was affirmed as a final order on (date), with respect to a workplace located at 8111 31st Street West, Rock Island, IL 61201.
Recent events (2)
- — I (S) $0
- — Z (S) $9126
More inspections at Techo-Bloc Corp
View Techo-Bloc Corp's full OSHA safety record →
More inspections in this industry (NAICS 444190)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346949514.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.