Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NBVC LANES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NBVC LANES in 2583 DODSON STREET, PORT HUENEME, CA 93041 (NAICS 713950). OSHA activity number 346952252.

Watch Nbvc Lanes — free Get an email when a new federal OSHA severe-injury report for Nbvc Lanes is published. One employer, no account, unsubscribe in one click.
Establishment
NBVC LANES
Site address
2583 DODSON STREET
City
PORT HUENEME
State
CA
ZIP
93041
Mailing
2583 DODSON STREET, PORT HUENEME, CA 93041
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713950
Employees
10
Ownership type
D

6 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.101(b):"Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6. Section 3.3.1 of the CGA Pamphlet P-1-1965 refers to storing cylinders in accordance with CGA and NFPA standards. The CGA Pamphlet P-1-1991 Section 3.7.4.1 states that "All compressed gas cylinders in service or in storage shall be secured to prevent from falling."  NBVC Lanes Kitchen: In front of the kitchen electrical panel, two compressed  nitrogen cylinders were upright and unsecure from displacement. The cylinders were directly in front of an electrical panel blocking its access and was used as an apron rack.   Employees were exposed to struck- by and electrical shock hazards.
Recent events (1)
  • — Z (S) $0

1910.132 E

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.132(e): The employer did not ensure that employees were not using defective or damaged personal protective equipment in the workplace.  On and/or before August 28 2023, employee(s) used safety glasses/goggles to protect their eyes from chemical splash during maintenance activities. The employer did not ensure that the eye protection used was in working condition and free of defects such as stretched out band and dirt obstructing employee's view. This condition potentially exposed employee(s) to eye hazards.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by in-going nip points, rotating parts, and/or flying chips and sparks:  Pin Setter Area: On and/or before September 28, 2023 employee(s) walked past the pin setter machines to service them during times of operation. The side(s) of the machines located at walkway isles were not guarded. This condition potentially exposed employee(s) to unguarded moving machine parts and/or amputation hazard(s).
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 3 instances 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling.  Back of bowling alley: On and/or before August 28 2023, the employer did not ensure that the Air King fans and microwave were installed according to their listing and labeling. This condition potentially exposed employee(s) to electrical shock hazards in the following locations:  a) North Exit b) Next to Compressor Room c) Mechanic Shop
Recent events (1)
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less was used for storage:  Bowling Center Kitchen: On and/or before August 28, 2023, the employer permitted materials to be stored directly in front of the electrical panel(s). This condition interferes with access and immediate shutdown of a circuit in the panel, particularly in the event of an emergency. Employee(s) were exposed to the potential of shock and/or fire hazard(s)
Recent events (1)
  • — Z (S) $0

1910.308 B02

Serious Gravity 5 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.308(b)(2): At this establishment the employer failed to ensure that all required means of egress lighting, illuminated exit signs, and all other lights necessary to provide illumination were maintained in operable condition(s).  Where emergency lighting was necessary, the system was not arranged so that the failure of any individual lighting element, such as the burning out of a light bulb, cannot leave any space in total darkness.  Back of bowling alley: On and/or before August 28, 2023, the employer did not ensure that exit signs and emergency lighting were in operable condition for the safe egress of employees. This condition potentially exposed them to burns and/or suffocation hazard(s) in the following locations:  a) North Exit b) South Exit c) Emergency light near north exit
Recent events (1)
  • — Z (S) $0

NBVC LANES

View NBVC LANES's full OSHA safety record →