Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AARON'S FAMILY FUN CENTER in 17070 AARON LANE, BELTON, MO 64012 (NAICS 713950). OSHA activity number 348918145.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AARON'S FAMILY FUN CENTER
- Site address
- 17070 AARON LANE
- City
- BELTON
- State
- MO
- ZIP
- 64012
- Mailing
- 17070 AARON LANE, BELTON, MO 64012
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713950
- Employees
- 20
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.212 A02
- Issued
- Jun 18, 2026
- Penalty
- Initial $2,894 · Current $1,592 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: At the worksite located at 17070 Aaron Lane, Belton, Missouri: Employees were exposed to caught in hazards when working in and around the Brunswick GS-X pinsetters. The pinsetters were operating without manufacturer required guarding on the pinsetters to include the elevators and distributors.
Recent events (2)
- · I (S) $1591.7
- · Z (S) $2894
1910.303 G01 I
- Issued
- Jun 18, 2026
- Penalty
- Initial $1,929 · Current $1,061 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i): Sufficient access and working space was not provided for circuit breaker panels to permit ready and safe operation and maintenance. At the worksite located at 17070 Aaron Lane, Belton, Missouri: Employees were exposed to electric shock hazards when accessing electrical panels in the pin setting area. The employer did not maintain adequate working space in front of the panel. 1. Electrical panels in the pin setting area of The Den were blocked by chairs. 2. Electrical panels in the pin setting area were blocked by a ladder.
Recent events (2)
- · I (S) $1060.95
- · Z (S) $1929
1910.1200 E01
- Issued
- Jun 18, 2026
- Abate by
- Jul 16, 2026
- Penalty
- Initial $2,270 · Current $1,249 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: At the worksite located at 17070 Aaron Lane, Belton, Missouri: Employees were exposed to chemicals such as lane conditioner, isopropyl alcohol, and gloss restorer when cleaning the bowling lanes. The chemicals may cause eye irritation, skin irritation, and respiratory damage. The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program.
Recent events (2)
- · I (O) $1248.5
- · Z (S) $2270
More inspections in this industry (NAICS 713950)