EXETER, NH —
OSHA Inspection: GREASE MONKEY, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GREASE MONKEY, LLC in 96 PORTSMOUTH AVE, EXETER, NH 03833 (NAICS 811111). OSHA activity number 346956394.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREASE MONKEY, LLC
- Site address
- 96 PORTSMOUTH AVE
- City
- EXETER
- State
- NH
- ZIP
- 03833
- Mailing
- 5575 DTC PKWY SUITE 100, GREENWOOD VILLAGE, CO 80111
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 10
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 20, 2023
- Abate by
- Nov 24, 2023
- Penalty
- Initial $10,046 · Current $5,023 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing hazards when using a vehicle lift that had not been inspected by a qualified person for over two years and had numerous broken strains on the lifting cable. Location 1 : Bay 4 lift #2 On or about 9/1/2023, employees using a Rotary 10,000 lb. capacity lift serial number CNP10A0027 were exposed to a crushing hazard when the lift had not been inspected by a qualified person. Location 2: Bay 4 lift #3 On or about 9/1/2023, employees using a Rotary 10,000 lb. capacity lift serial number AFM97D1350 were exposed to a crushing hazard when the lift had not been inspected by a qualified person. Location 3: Bay 3 lift #1 On or about 9/1/2023, employees using a Rotary 10,000 lb. capacity lift serial number NFF13I0062 were exposed to a crushing hazard when the lift had not been inspected by a qualified person.
Recent events (3)
- — F (S) $5023
- — C (S) $10046
- — Z (S) $10046
1910.28 B03 I
- Issued
- Oct 20, 2023
- Penalty
- Initial $8,036 · Current $0 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(i): 29 CFR 1910.28(b)(3)(i): The employer did not ensure that each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following methods listed in 29 CFR 1910.28(b)(3)(i)(A)-(D): Location: Bays 1 and 2 On or about 9/1/2023 employees were not protected from a 7 foot fall hazard while working around an unguarded floor hole.
Recent events (3)
- — F (O) $0
- — C (S) $8036
- — Z (S) $8036
1910.157 E02
- Issued
- Oct 20, 2023
- Abate by
- Nov 24, 2023
- Penalty
- Initial $6,026 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(e)(2):Portable fire extinguishers were not visually inspected at least monthly: Location: shop area On or about 9/1/2023, portable fire extinguishers were not inspected at least monthly.
Recent events (3)
- — F (O) $0
- — C (S) $6026
- — Z (S) $6026
1910.215 A04
- Issued
- Oct 20, 2023
- Penalty
- Initial $8,036 · Current $4,018 Reduced
General-duty citation text
29 CFR 1910.215(a)(4):Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Location: shop area On or about 9/1/2023, the work rest on a one horsepower Sears and Roebuck bench grinder was not set to within one eighth of an inch from the abrasive grinding wheel.
Recent events (3)
- — F (S) $4018
- — C (S) $8036
- — Z (S) $8036
1910.305 B02 I
- Issued
- Oct 20, 2023
- Abate by
- Nov 24, 2023
- Penalty
- Initial $10,046 · Current $5,023 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i):Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: Location: lower level pit area On or about 9/1/2023, Employees were exposed to electrical shock and burns from a Saylor - Beall model VT 730-80 air compressor that did not have a cover on the motor junction box.
Recent events (3)
- — F (S) $5023
- — C (S) $10046
- — Z (S) $10046
1910.22 A02
- Issued
- Oct 20, 2023
- Abate by
- Nov 24, 2023
- Penalty
- Initial $24,109 · Current $7,033 Reduced
General-duty citation text
29 CFR 1910.22(a)(2):29 CFR 1910.22(a)(2): The employer did not ensure that the floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided. Location: Lower level pit area on or about 9/1/2023, employees were exposed to a slip/fall hazard when the floor in the lower level under the East stairway was not kept dry to the extent feasible. Grease Monkey International, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.22(a)(2), which was contained in OSHA inspection number 1522224, citation number 1, item number 1 and was affirmed as a final order on 09/17/2021, with respect to a workplace located at 808 Willowbrook Drive Hinesville, Ga 31313.
Recent events (3)
- — F (S) $7033
- — C (R) $24109
- — Z (R) $24109
1910.303 B01 I
- Issued
- Oct 20, 2023
- Abate by
- Nov 24, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1)(i):Suitability for installation and use in conformity with the provisions of this subpart; Note to paragraph (b)(1)(i) of this section: Suitability of equipment for an identified purpose may be evidenced by listing or labeling for that identified purpose. Location: work bench On or about 9/1/2023, A relocatable power tap providing power to a Sears and Roebuck 1 H.P. bench grinder serial 82010004 was plugged into an extension cord and not directly into a permanent outlet.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811111)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346956394.