1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: CEMSTONE READY MIX

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of CEMSTONE READY MIX in 1190 COUNTY ROAD G, NEW RICHMOND, WI 54017 (NAICS 423320). OSHA activity number 346961063.

Watch Cemstone Ready MIX — free Get an email when a new federal OSHA severe-injury report for Cemstone Ready MIX is published. One employer, no account, unsubscribe in one click.
Establishment
CEMSTONE READY MIX
Site address
1190 COUNTY ROAD G
City
NEW RICHMOND
State
WI
ZIP
54017
Mailing
1190 COUNTY ROAD G, NEW RICHMOND, WI 54017
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423320
Employees
29
Ownership type
A

6 citations on file for this inspection.

1910.146 F

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $10046.00 · Current $6028.00 Reduced
29 CFR  1910.146(f): The entry permit that documented compliance with this section and authorized entry into a permit space did not identify the requirements in (f)(1)-(15) of this section:   (a) Wet Batch Plant Mixer (Plant 23); On or about August 7, 2023 and at times prior, entry was made into the mixing drum to chip out dried concrete. The entry permits did not include required information including, but not limited to, the name of the attendant, results of initial and periodic atmospheric testing, and verification of rescue service capabilities.
Recent events (2)
  • — I (S) $6027.6
  • — Z (S) $10046

1910.146 K01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.146(k)(1): An employer who designates rescue and emergency services, pursuant to paragraph (d)(9) of this section shall evaluate the prospective rescuer's ability by the criteria set in this section, (k)(1)(i) - (k)(1)(v):   (a) Wet Batch Plant Mixer (Plant 23); On or about August 7, 2023 and at times prior, entry was made into the mixing drum to chip out dried concrete. The employer did not evaluate the rescue service capabilities per the requirements.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $10046.00 · Current $6028.00 Reduced
29 CFR  1910.147(c)(4)(ii):  Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  (a) Wet Batch Plant Mixer (Plant 23); The energy control procedure utilized for cleaning behind the wet batch plant mixer did not include all machine specific procedural steps for isolating each energy source, to include but not be limited to, the emergency tilt system motor.
Recent events (2)
  • — I (S) $6027.6
  • — Z (S) $10046

1910.1053 D06 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8036.00 · Current $0.00 Reduced
29 CFR  1910.1053(d)(6)(i):  Within 15 working days after completing an exposure assessment in accordance with paragraph (d) of this section, the employer did not individually notify each affected employee in writing of the results of that assessment or post the results in an appropriate location accessible to all affected employees:  (a) Wet Batch Plant Mixer (Plant 23);  The employer did not notify employee(s) in writing or post the respirable crystalline silica results.   The employee was exposed over the action level per air monitoring conducted on or about June 5, 2023.
Recent events (2)
  • — I (O) $0
  • — Z (S) $8036

1910.1053 K01 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1053(k)(1)(i): The employer did not make and maintain an accurate record of all exposure measurements taken to assess employee exposure to respirable crystalline silica, as prescribed in paragraph (d) of this section:   (a) Wet Batch Plant Mixer (Plant 23); The employer did not maintain an accurate record of respirable crystalline silica results per exposure measurements collected on June 5, 2023.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.146 D

Repeat Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $20092.00 · Current $12055.00 Reduced
29 CFR  1910.146(d):Under the permit space program required by paragraph (c)(4) of this section the employer did not ensure that the requirements of (d)(1) through (d)(14) were met:  (a) Wet Batch Plant Mixer (Plant 23); On or about August 7, 2023 and at times prior, entry was made into the mixing drum to chip out dried concrete. The employer did not ensure applicable requirements per the permit space program were implemented, prior to and during entry.  Cemstone Ready Mix was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.146(d), which was contained in OSHA inspection number 1630390, citation number 1, item number 3b and was affirmed as final order on April 20, 2023, with respect to a workplace located at 1190 County Road G, New Richmond, WI 54017.
Recent events (2)
  • — I (R) $12055.2
  • — Z (R) $20092

View CEMSTONE READY MIX's full OSHA safety record →