Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R&A STONE & STUCCO, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of R&A STONE & STUCCO, LLC in 1653 W STATE STREET, EAGLE, ID 83616 (NAICS 238140). OSHA activity number 346962723.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R&A Stone & Stucco, LLC — free Get an email when a new federal OSHA severe-injury report for R&A Stone & Stucco, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1653 W STATE STREET
City
EAGLE
State
ID
ZIP
83616
Mailing
3511 E DOROTHY LN, NAMPA, ID 83651
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 3, 2024
Abate by
Jan 16, 2024
Penalty
Initial $4,018 · Current $2,009 Reduced
29 CFR  1926.451(b)(1):Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  (a): On September 7th, 2023 and times prior, employees were working on scaffolding which was only half planked.  Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (S) $2009
  • — Z (S) $4018

1926.451 G04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 3, 2024
Abate by
Jan 16, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(4)(i):Guardrail systems were not installed along all open sides and ends of platforms.  (a): On September 7th, 2023 and times prior, employees were working on scaffolding that did not have guardrails on open sides, leading to potential falls of 13.5 feet.  Abatement Note: Abatement certification  and documentation is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 3, 2024
Abate by
Jan 23, 2024
Penalty
Initial $4,688 · Current $2,344 Reduced
29 CFR  1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  (a): On September 7th, 2023 and times prior, employees accessed the scaffolding by use of crossbraces, buckets, and the ends of the scaffold.    Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (S) $2344
  • — Z (S) $4688

1926.451 E09 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 3, 2024
Abate by
Jan 16, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.451(e)(9)(iv):Cross braces on tubular welded frame scaffolds were used as a means of access or egress.  (a) On September 7th, 2023 and times prior, employees accessed the scaffolding using the frames instead of ladders or other appropriate measures of access and egress so that they could perform stucco activities.   Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 H02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 3, 2024
Abate by
Jan 30, 2024
Penalty
Initial $2,009 · Current $1,005 Reduced
29 CFR  1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:Note:  This requirement does not apply to float (ship) scaffolds where an edging of 3/4 inch x 1 1/2 inch (2 x 4 cm) wood or equivalent was used in lieu of toeboards.   (a) On September 7th, 2023 and times prior,  employees that were working below the scaffold were not protected from falling materials such as a bucket with stucco and application tools.  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (S) $1004.5
  • — Z (S) $2009

1926.452 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 3, 2024
Abate by
Jan 16, 2024
Penalty
Initial $4,018 · Current $2,009 Reduced
29 CFR  1926.452(c)(2):Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:  (a) On September 7th, 2023 and times prior, employees were working on a scaffold applying stucco that was not fully braced in multiple areas throughout the scaffold.  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (S) $2009
  • — Z (S) $4018

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346962723.