BROADVIEW, IL ·
OSHA Inspection: BEAM GLOBAL
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BEAM GLOBAL in 2600 S. 25TH AVE. SUITE Z, BROADVIEW, IL 60155 (NAICS 237130). OSHA activity number 346973811.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BEAM GLOBAL
- Site address
- 2600 S. 25TH AVE. SUITE Z
- City
- BROADVIEW
- State
- IL
- ZIP
- 60155
- Mailing
- 2600 S. 25TH AVE. SUITE Z, BROADVIEW, IL 60155
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 50
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 D
- Issued
- Jan 12, 2024
- Penalty
- Initial $14,063 · Current $9,745 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) Module assembly floor- On or about August 30, 2023, employees were exposed to machine hazards associated with moving parts. One employee, Packer, was clearing a Sheffield Automatic Strip Cutting Machine Model #C-530 while the machine was powered on, which resulted in an amputation to the left middle finger. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- · I (S) $9745
- · Z (S) $14063
1910.212 A03 II
- Issued
- Jan 12, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Module assembly floor- On or about August 30, 2023, employees required to operate the Sheffield Automatic Strip Cutting Machine Model #C-530 were exposed to machine hazards associated with moving parts. The employer failed to provide adequate guarding Sheffield Automatic Strip Cutting Machine Model #C-530. Employees were thereby exposed to the hazards associated with unguarded points of operation during the operating cycles.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Beam Global
View Beam Global's full OSHA safety record →
More inspections in this industry (NAICS 237130)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 346973811.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.