BUFFALO, NY —
OSHA Inspection: FAJARDO CONSTRUCTION CORP
Special Programs inspection · Safety discipline
At a glance
On , OSHA opened a special Programs safety inspection of FAJARDO CONSTRUCTION CORP in 77 JUNIATA PL, BUFFALO, NY 14210 (NAICS 238160). OSHA activity number 346977838.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FAJARDO CONSTRUCTION CORP
- Site address
- 77 JUNIATA PL
- City
- BUFFALO
- State
- NY
- ZIP
- 14210
- Mailing
- 392 DARTMOUTH AVENUE, BUFFALO, NY 14215
What kind of inspection was it?
- Inspection type
- Special Programs (K)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- Sep 25, 2023
- Penalty
- Initial $3,795 · Current $3,795
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 9/15/2023, at a home and garage roof project located at 77 Juanita Pl Buffalo NY; employees were painting on the roof of a two story home. The roof had multiple pitches including an 5 in 12 pitch with an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $3795
1926.1053 B01
- Issued
- Sep 25, 2023
- Penalty
- Initial $2,277 · Current $2,277
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a) On or about 9/15/2023 at the roof area of the site, side rails of the extension ladder did not extended 3 feet above the upper landing surface being accessed. Employees were exposed to falls. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $2277
More inspections at Fajardo Construction Corp