MASSILLON, OH —
OSHA Inspection: NATIONAL ENCLOSURE COMPANY LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NATIONAL ENCLOSURE COMPANY LLC in 4075 MILLENNIUM BLVD SE, MASSILLON, OH 44646 (NAICS 332312). OSHA activity number 346985948.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL ENCLOSURE COMPANY LLC
- Site address
- 4075 MILLENNIUM BLVD SE
- City
- MASSILLON
- State
- OH
- ZIP
- 44646
- Mailing
- 4075 MILLENNIUM BLVD SE, MASSILLON, OH 44646
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 43
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Oct 4, 2023
- Penalty
- Initial $10,938 · Current $6,563 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about September 07, 2023, an employee was exposed to machine hazards associated with moving mechanical parts and struck by hazards during service and maintenance of the CNC housing of the ITALMAC CNC Machine. The employer failed to develop, document, and utilize machine specific procedures for the ITALMAC CNC Machine to protect employees from machine servicing hazards. As a result, hazardous energies including pneumatic, and electrical were not isolated, exposing the employee(s) to struck by hazards associated with the reciprocating movements of the CNC housing unit.
Recent events (2)
- — I (S) $6563
- — Z (S) $10938
1910.147 D
- Issued
- Oct 4, 2023
- Abate by
- Nov 22, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about September 07, 2023, an employee was exposed to machine hazards associated with moving mechanical parts and struck by hazards during service and maintenance of the CNC housing of the ITALMAC CNC Machine. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6), were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Oct 4, 2023
- Abate by
- Nov 22, 2023
- Penalty
- Initial $7,813 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about September 07, 2023, the employer did not ensure that the ITALMAC CNC Machine was effectively guarded to prevent employees from entering the hazardous area in that the interlocked gate was able to be closed behind an employee making entry. Employee(s) working inside the ITALMAC CNC Machine area were exposed to struck by hazards associated with the reciprocating movements of the spindle housing.
Recent events (2)
- — I (S) $0
- — Z (S) $7813
1910.147 C07 I A
- Issued
- Oct 4, 2023
- Penalty
- Initial $10,938 · Current $6,563 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: On or about September 07, 2023, an employee was exposed to machine hazards associated with moving mechanical parts and struck by hazards during service and maintenance of the CNC housing of the ITALMAC CNC Machine. The employer failed to provide training to ensure authorized employees understood the purpose and function of the energy control program and employees had acquired the knowledge and skills required for the safe application, usage, and removal of energy controls.
Recent events (2)
- — I (S) $6563
- — Z (S) $10938
More inspections at National Enclosure Company LLC
View National Enclosure Company LLC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346985948.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.