Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NATIONAL ENCLOSURE COMPANY LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NATIONAL ENCLOSURE COMPANY LLC in 4075 MILLENNIUM BLVD SE, MASSILLON, OH 44646 (NAICS 332312). OSHA activity number 346985948.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Enclosure Company LLC — free Get an email when a new federal OSHA severe-injury report for National Enclosure Company LLC is published. One employer, no account, unsubscribe in one click.
Site address
4075 MILLENNIUM BLVD SE
City
MASSILLON
State
OH
ZIP
44646
Mailing
4075 MILLENNIUM BLVD SE, MASSILLON, OH 44646
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
43
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 4, 2023
Penalty
Initial $10,938 · Current $6,563 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about September 07, 2023, an employee was exposed to machine hazards associated with moving mechanical parts and struck by hazards during service and maintenance of the CNC housing of the ITALMAC CNC Machine. The employer failed to develop, document, and utilize machine specific procedures for the ITALMAC CNC Machine to protect employees from machine servicing hazards. As a result, hazardous energies including pneumatic, and electrical were not isolated, exposing the employee(s) to struck by hazards associated with the reciprocating movements of the CNC housing unit.
Recent events (2)
  • — I (S) $6563
  • — Z (S) $10938

1910.147 D

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 4, 2023
Abate by
Nov 22, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about September 07, 2023, an employee was exposed to machine hazards associated with moving mechanical parts and struck by hazards during service and maintenance of the CNC housing of the ITALMAC CNC Machine. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6), were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 4, 2023
Abate by
Nov 22, 2023
Penalty
Initial $7,813 · Current $0 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about September 07, 2023, the employer did not ensure that the ITALMAC CNC Machine was effectively guarded to prevent employees from entering the hazardous area in that the interlocked gate was able to be closed behind an employee making entry. Employee(s) working inside the ITALMAC CNC Machine area were exposed to struck by hazards associated with the reciprocating movements of the spindle housing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7813

1910.147 C07 I A

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 4, 2023
Penalty
Initial $10,938 · Current $6,563 Reduced
29 CFR  1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  On or about September 07, 2023, an employee was exposed to machine hazards associated with moving mechanical parts and struck by hazards during service and maintenance of the CNC housing of the ITALMAC CNC Machine. The employer failed to provide training to ensure authorized employees understood the purpose and function of the energy control program and employees had acquired the knowledge and skills required for the safe application, usage, and removal of energy controls.
Recent events (2)
  • — I (S) $6563
  • — Z (S) $10938

View National Enclosure Company LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346985948.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.