Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DEL VALLE GROUP, LLC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of DEL VALLE GROUP, LLC. in PIER #4 OLD SAN JUAN, SAN JUAN, PR 00936 (NAICS 237990). OSHA activity number 346988124.

Watch DEL Valle Group, LLC. — free Get an email when a new federal OSHA severe-injury report for DEL Valle Group, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
PIER #4 OLD SAN JUAN
City
SAN JUAN
State
PR
ZIP
00936
Mailing
P.O. BOX 2319, TOA BAJA, PR 00951
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237990
Employees
275
Ownership type
A

4 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $11333.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury:  a.   On or about 19 September 2023, at Pier #4, Cruises Terminal, San Juan, PR.  Employees performing marine construction related activities standing inside the water from a working platform with an electrical tool were not trained on the hazards related to electrical and proper use and operation of the electrical tool.   NOTE:	Documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $11333
  • — Z (S) $16131

1926.404 B01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $16131.00 · Current $11333.00 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure, and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:  a.   On or about 19 September 2023, at Pier #4, Cruises Terminal, San Juan, PR.  Employees performing marine construction related activities standing inside the water from a working platform were working with an electrical tool connected with a defective/nonoperational ground-fault circuit interrupter.   b. On or about 19 September 2023, at Pier #4, Cruises Terminal, San Juan, PR. Employees performing marine construction related activities were working with an electrical tool connected to a receptable at the end of the electrical cord not being protected with a ground-fault circuit interrupter.   NOTE: 	Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (S) $11333
  • — Z (S) $16131

1926.405 J02 II

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $16131.00 · Current $11334.00 Reduced
29 CFR  1926.405(j)(2)(ii): A receptacle installed in a wet or damp location was not designed for the location:  a.   On or about 19 September 2023, at Pier #4, Cruises Terminal, San Juan, PR.  Employees were exposed to electrical and drowning hazards as employees engaged in marine construction were standing inside the water from a working platform with an electrical tool.  The electrical tool being used was connected to an electrical receptacle not protected against the weather and water elements.        NOTE: 	Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (S) $11334
  • — Z (S) $16131

1926.416 A03

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $16131.00 · Current $0.00 Reduced
29 CFR  1926.416(a)(3): The employer began work without determining if employees could contact any part of an energized circuit:   a.   On or about 19 September 2023, at Pier #4, Cruises Terminal, San Juan, PR.  Employees were exposed to electrical and drowning hazards as employees engaged in marine construction were standing inside the water from a working platform with an electrical hand tool.  The employer did not to take the necessary steps to determine whether or not there was buried electrical equipment that could have been contacted while performing work.     NOTE: 	Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (O) $0
  • — Z (S) $16131

View DEL VALLE GROUP, LLC.'s full OSHA safety record →