HOUSTON, TX —
OSHA Inspection: MIL, LTD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MIL, LTD in 1912 BUSCHONG ST, HOUSTON, TX 77039 (NAICS 332323). OSHA activity number 347009268.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MIL, LTD
- Site address
- 1912 BUSCHONG ST
- City
- HOUSTON
- State
- TX
- ZIP
- 77039
- Mailing
- 1912 BUSCHONG ST, HOUSTON, TX 77039
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- Employees
- 250
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 14, 2023
- Abate by
- Dec 11, 2023
- Penalty
- Initial $9,393 · Current $5,636 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. On or about September 20, 2023, employees were exposed to a caught-by hazard when changing the blade on a Cosen band saw without energy control procedures being developed, written, or utilized. b. On or about October 3, 2023, an employee was exposed to caught-by hazard when changing the blade on a FMB band saw without energy control procedures being developed, written, or utilized.
Recent events (2)
- — I (S) $5635.8
- — Z (S) $9393
1910.147 D03
- Issued
- Nov 14, 2023
- Abate by
- Dec 11, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3):All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about October 3, 2023, an employee was exposed to a caught-by hazard when changing the blade on the FMB band saw without isolating the saw from the energy source.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Nov 14, 2023
- Abate by
- Dec 11, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about September 20, 2023, employees were exposed to a caught-by hazard while replacing the blade on the Cosen band saw without having applied a lock on the energy control device.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Nov 14, 2023
- Abate by
- Dec 11, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i):The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a. On or about September 20, 2023, employees were exposed to a caught-by hazard when changing the blade on a Cosen band saw without having been trained on the control of hazardous energy. b. On or about October 3, 2023, an employee was exposed to caught-by hazard when changing the blade on a FMB band saw without having been trained on the control of hazardous energy.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Nov 14, 2023
- Abate by
- Dec 11, 2023
- Penalty
- Initial $9,393 · Current $5,636 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about October 3, 2023, an employee was exposed to an caught-by hazard while operating a FMB band saw that was not guarded to protect the operator from the unused portion of the saw blade.
Recent events (2)
- — I (S) $5635.8
- — Z (S) $9393
1910.212 A03 II
- Issued
- Nov 14, 2023
- Abate by
- Dec 11, 2023
- Penalty
- Initial $9,393 · Current $5,636 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about October 3, 2023, an employee was exposed to a caught-by hazard while using a Peddinghaus punch without a guard to protect employees from the point of operation.
Recent events (2)
- — I (S) $5635.8
- — Z (S) $9393
More inspections at MIL, LTD
View MIL, LTD's full OSHA safety record →
More inspections in this industry (NAICS 332323)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347009268.