OSHA Inspection: WALTER ST. CLAIR ROOFING, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of WALTER ST. CLAIR ROOFING, INC. in 139 RITCHIE AVENUE, CINCINNATI, OH 45215 (NAICS 238160). OSHA activity number 347009300.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Walter ST. Clair Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Walter ST. Clair Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
139 RITCHIE AVENUE
City
CINCINNATI
State
OH
ZIP
45215
Mailing
4717 VINE STREET, CINCINNATI, OH 45217
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 20, 2023
Abate by
Dec 8, 2023
Penalty
Initial $5,156 · Current $1,500 Reduced
29 CFR  1926.20(b)(2): Accident prevention responsibilities. Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  a) On or about October 3, 2023, the employer did not ensure that frequent and regular inspections were being conducted for the jobsite at 139 Ritchie Avenue, Cincinnati, OH 45215. As a result, employees were exposed to a fall hazard of 8'11" from a lack of fall protections and improper ladder usage. Additionally, employees were exposed to electrical shock hazards from working in close proximity to live electrical power lines.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $5156

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 20, 2023
Abate by
Dec 8, 2023
Penalty
Initial $5,156 · Current $0 Reduced
29 CFR  1926.416(a)(1): Protection of employees. No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.   a) On or about October 3, 2023, the employer did not ensure that employees working within three feet proximity of a live electrical wire were protected against electric shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5156

1926.1053 B12

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 20, 2023
Abate by
Dec 8, 2023
Penalty
Initial $5,156 · Current $0 Reduced
29 CFR  1926.1053(b): Use. The following requirements apply to the use of all ladders, including job-made ladders, except as otherwise indicated: (12)Ladders shall have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment, except as provided in 1926.951(c)(1) of this part.  a) On or about October 3, 2023, the employer did not ensure that employees using a ladder to access the roof near energized electrical equipment were using a ladder with nonconductive siderails.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5156

1926.501 B13

Deleted Repeat Gravity 10 1 instance 1 exposed
Issued
Oct 20, 2023
Abate by
Dec 8, 2023
Penalty
Initial $10,313 · Current $0 Reduced
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a) On or about October 3, 2023, the employer failed to ensure that employees performing re-roofing activities on a residential home were utilizing a fall protection system. As a result, an employee was exposed to a fall height measured at 8'11".   Walter St. Clair Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1594147, citation number 1, item number 2 and was affirmed as a final order on July 27, 2022, with respect to a workplace located at 3742 Marburg Ave., Cincinnati, OH 45209.
Recent events (2)
  • — I (R) $0
  • — Z (R) $10313

1926.1053 B01

Repeat Gravity 10 1 instance 1 exposed
Issued
Oct 20, 2023
Abate by
Dec 8, 2023
Penalty
Initial $10,313 · Current $2,500 Reduced
29 CFR  1926.1053(b): Use. The following requirements apply to the use of all ladders, including job-made ladders, except as otherwise indicated: (1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a) On or about October 3, 2023, the employer failed to ensure that the Little Giant ladder that was being utilized by employees performing re-roofing activities to access the roof was extended at least 3 feet above the upper landing. As a result, an employee was exposed to a fall hazard of 8'11".  Walter St. Clair Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1053(b)(1), which was contained in OSHA inspection number 1594147, citation number 1, item number 2 and was affirmed as a final order on (date), with respect to a workplace located at 3742 Marburg Avenue, Cincinnati, OH 45209.
Recent events (2)
  • — I (R) $2500
  • — Z (R) $10313

1926.503 B01

Other-than-serious 1 instance 1 exposed
Issued
Oct 20, 2023
Abate by
Dec 8, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.503(b)(1): Certification of training. The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training.  a) On or about October 3, 2023, the employer did not ensure that written training records for fall protection were being maintained in that the employer did not have training records for employees working at 139 Ritchie Avenue, Cincinnati, OH 45215.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Walter ST. Clair Roofing, INC.'s full OSHA safety record →