NEWNAN, GA —
OSHA Inspection: DIMAS ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DIMAS ROOFING, INC. in LOT 5 STARR PL, NEWNAN, GA 30263 (NAICS 238160). OSHA activity number 347012130.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIMAS ROOFING, INC.
- Site address
- LOT 5 STARR PL
- City
- NEWNAN
- State
- GA
- ZIP
- 30263
- Mailing
- 4417 GLEN HEIGHTS TRAIL, SNELLVILLE, GA 30039
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Apr 1, 2024
- Penalty
- Initial $4,563 · Current $4,563
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b) a) Lot # 5: On or about October 4, 2023, and times prior, the employer exposed employees to fall hazards, in that the employer did not provide a full body harness with a D-ring for employees to tie off from when installing a roof at a height of 20 feet.
Recent events (1)
- — Z (S) $4563
1926.1053 B01
- Issued
- Apr 1, 2024
- Penalty
- Initial $3,042 · Current $3,042
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a) Lot # 5: On or about October 4, 2023, and times prior, the employer exposed employees to fall hazards, in that the employer did not provide employees with portable ladders that were extended 3 feet past the lip of the upper landing.
Recent events (1)
- — Z (S) $3042
More inspections at Dimas Roofing, INC.
View Dimas Roofing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347012130.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.