OSHA Inspection: AMI, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMI, INC. in 4365 BROWNS BRIDGE ROAD, CUMMING, GA 30041 (NAICS 238160). OSHA activity number 347019036.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AMI, INC. — free Get an email when a new federal OSHA severe-injury report for AMI, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AMI, INC.
Site address
4365 BROWNS BRIDGE ROAD
City
CUMMING
State
GA
ZIP
30041
Mailing
1274 LOWER DOWDA MILL, JASPER, GA 30143
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
12
Ownership type
A

3 citations on file for this inspection.

1926.501 B11

Serious Gravity 5 1 instance 11 exposed
Issued
Nov 2, 2023
Penalty
Initial $5,358 · Current $3,215 Reduced
29 CFR  1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels were not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems.  a) Commercial Bank, Roof: On or about 10/7/2023, the employer exposed employees to fall hazards, in that no fall protection system was provided to employees while removing shingles from the roof.
Recent events (2)
  • — I (S) $3214.8
  • — Z (S) $5358

1926.1053 B01

Serious Gravity 5 1 instance 11 exposed
Issued
Nov 2, 2023
Penalty
Initial $5,358 · Current $3,215 Reduced
29 CFR  1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet above the upper landing surface to which the ladder was used to gain access.  a) Commercial Bank, East side wall: On 10/7/2023, the employer exposed employees to fall hazards, in that the extension ladder was not extended at least 3 feet above the upper landing to give employees a safe means of access/egress.
Recent events (2)
  • — I (S) $3214.8
  • — Z (S) $5358

1926.552 A01

Other-than-serious 1 instance 1 exposed
Issued
Nov 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.552(a)(1):The employer did not comply with manufacturer's specifications and limitations applicable to the operation of all hoists and elevators.   a) Commercial Bank, South Front Entrance: On 10/7/2023, the employer exposed employees to struck-by hazards, in that the employer did not comply with the manufacturer's specifications of the TranzSporter Platform Hoist replaced the damaged wire cable with a mountain climbing type rope.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View AMI, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347019036.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.