OSHA Inspection: APG POLYTECH, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of APG POLYTECH, LLC in 27610 HUNTINGTON ROAD, APPLE GROVE, WV 25502 (NAICS 325211). OSHA activity number 347026296.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch APG Polytech, LLC — free Get an email when a new federal OSHA severe-injury report for APG Polytech, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
APG POLYTECH, LLC
Site address
27610 HUNTINGTON ROAD
City
APPLE GROVE
State
WV
ZIP
25502
Mailing
27610 HUNTINGTON ROAD, APPLE GROVE, WV 25502
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
171
Ownership type
A

11 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 3 instances 8 exposed
Issued
Mar 4, 2024
Abate by
Jun 27, 2024
Penalty
Initial $11,524 · Current $11,524

Hazardous substances E101M102

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment free from hazards associated with combustible dust when using and/or working near an industrial vacuum system:  (a) Building 55, CP3 West Pit: On or about September 22, 2023, and times prior, employees used a stationary industrial vacuum system to vacuum powdered TPA on the ground and equipment in the vertical pit. The Hi-Vac vacuum was located in a non-hazardous location; however, a hose sections was improperly connected and the improperly connected hose was not grounded and bonded causing an electrostatic discharge felt by employees.  (b) Building 55, TPA Unload Area: On or about October 4, 2023, and times prior, employees used a stationary industrial vacuum system to vacuum out large amounts of powdered TPA that spilled out onto the floor under a railcar due to an issue during the download process. The Hi-Vac vacuum was located in a non-hazardous location; however, a hose section was improperly connected and the improperly connected hose section was not grounded and bonded causing electrostatic discharge felt by employees.  (c) Building 55, TPS Barn and CP3 TPA Pit: On or about November 14, 2023, and times prior, the employer did not provide or require the use of flame-retardant and no-static generating clothing to employees when working areas where combustible dust could be present.
Recent events (3)
  • — F (S) $11524
  • — C (S) $11524
  • — Z (S) $11524

1910.22 A01

Deleted Serious Gravity 5 2 instances 4 exposed
Issued
Mar 4, 2024
Abate by
Mar 14, 2024
Penalty
Initial $11,524 · Current $0 Reduced

Hazardous substances E101M102

29 CFR  1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  (a) Building 55, TPA Barn: On or about October 12, 2023, and times prior, combustible dust covered electrical conduit, receptacles, mechanical equipment, and other horizontal surfaces, exposing employees to flash fires and explosion hazards.   (b) Building 55, Pit: On or about October 12, 2023, and times prior, combustible dust covered mechanical equipment and other horizontal surfaces, exposing employees to flash fires and explosion hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $11524
  • — Z (S) $11524

1910.22 A02

Deleted Serious Gravity 5 2 instances 4 exposed
Issued
Mar 4, 2024
Abate by
Mar 14, 2024
Penalty
Initial $0 · Current $0

Hazardous substances E101M102

29 CFR 1910.22(a)(2): The employer did not ensure that the  floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided.  a) Building 55, TPA Barn: On or about October 12, 2023, and times prior, the employer did not keep the floor of the work area free from hazardous accumulations of combustible dusts, exposing employees to flash fires and explosion hazards.   (b) Building 55, Pit: On or about October 12, 2023, and times prior, the employer did not keep the floor of the work area free from hazardous accumulations of combustible dusts, exposing employees to flash fires and explosion hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.145 C03

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Mar 4, 2024
Abate by
Mar 21, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s).  (a) Building 55, TPA Barn: On or about October 11, 2023, and times prior, the employer did not ensure that safety signs were installed at the north and south entrance points to inform employees of the explosive hazards associated with TPA and the work being performed in the building.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.132 A

Deleted Serious Gravity 5 2 instances 5 exposed
Issued
Mar 4, 2024
Abate by
Mar 28, 2024
Penalty
Initial $11,524 · Current $0 Reduced

Hazardous substances E101M102

29 CFR  1910.132(a): Protective equipment was not used when necessary when a hazard of process or environment capable of causing injury or impairment of the body through physical contact was encountered.  (a) Building 55, TPA Barn: On or about October 12, 2023, and times prior, the employer did not provide or require the use of flame-retardant and non-static generating clothing necessary to protect employees from burns due to potential flash fires and/or explosions in areas where combustible dust was present.  (b) Building 55, CP3 West Pit: On or about November 14, 2023, and times prior, the employer did not provide or require the use of flame-retardant and non-static generating clothing necessary to protect employees from burns due to potential flash fires and/or explosions when working in areas where combustible dust is present.
Recent events (3)
  • — F (S) $0
  • — C (S) $11524
  • — Z (S) $11524

1910.146 D04 VIII

Deleted Serious Gravity 5 2 instances 5 exposed
Issued
Mar 4, 2024
Abate by
Mar 14, 2024
Penalty
Initial $11,524 · Current $0 Reduced
29 CFR  1910.146(d)(4)(viii):Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not ensure that employees properly used rescue and emergency equipment needed to comply with 29 CFR 1910.146(d)(9).  (a) Building 55, CP3 West Pit: On or about September 22, 2023, and times prior, a mechanical device was not available to retrieve two employees who were working in a vertical confined space pit approximately 11ft. 8in. deep. A rope was attached to the body harness and to a railing system around the confined space opening, exposing employees to asphyxiation and fire hazards.  (b) Building 55, CP3 West Pit: On or about November 14, 2023, and times prior, a mechanical device was not available to retrieve an employee who was working in a vertical confined space pit approximately 11ft. 8in deep. A 50ft. nylon rope was attached to a body harness and to a railing system around the confined space opening, exposing the employee to asphyxiation and fire hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $11524
  • — Z (S) $11524

1910.146 G01

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 4, 2024
Abate by
Jun 27, 2024
Penalty
Initial $0 · Current $11,524
29 CFR  1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146.  (a) Building 55: on or about October 12, 2023 and times prior, employees entering confined spaces had received training regarding  confined spaces, but had not adequately acquired an understanding, knowledge and skills necessary for the utilization of available devices to assist with the safe performance of their duties assigned under this section.
Recent events (3)
  • — F (S) $11524
  • — C (S) $0
  • — Z (S) $0

1910.140 C11 I

Other-than-serious 1 instance 4 exposed
Issued
Mar 4, 2024
Abate by
Jun 27, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.140(c)(11)(i): The employer did not ensure that each horizontal lifeline is designed, installed, and used under the supervision of a qualified person.  (a) Building 55, TPA Barn: On or about October 11, 2023, and times prior, employees use a horizontal lifeline anchored to beams that have not been approved as capable of supporting the required weight for each employee.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.140 C18

Other-than-serious 1 instance 4 exposed
Issued
Mar 4, 2024
Abate by
Jun 27, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.140(c)(18): The employer did not ensure that personal fall protection systems are inspected before initial use during each work shift for mildew, wear, damage, and other deterioration, and defective components are removed from service.  (a) Building 55, TPA Barn: On or about October 12, 2023, and times prior, employees use personal fall protection equipment provided by the employer that is not inspected prior to use, therefore the rusted/corroded steel snap hooks, rusted/corroded harness steel parts, and the discolored, TPA coated lanyards were not removed from service.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.157 C04

Other-than-serious 1 instance 4 exposed
Issued
Mar 4, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition.  (a) Building 55, North End of New Product Side: On or about October 11, 2023, there was a portable ABC fire extinguisher placed and available for use by employees that, while not discharged, reflected a charge of less than full.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.242 B

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Mar 4, 2024
Penalty
Initial $9,795 · Current $9,795
29 CFR  1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30psi.   (a) Building 55, TPA Barn: On or about October 11, 2023, and times prior, employees use unregulated compressed air measured over 90psi to clean dust and debris from their clothing and from railcars on the finished product side, exposing employees to lacerations and eye injuries.
Recent events (3)
  • — F (O) $9795
  • — C (S) $9795
  • — Z (S) $9795

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347026296.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.