COLD SPRING HARBOR, NY —
OSHA Inspection: NATIONAL FRAMERS HL CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NATIONAL FRAMERS HL CORP. in 112 HARBOR ROAD, COLD SPRING HARBOR, NY 11724 (NAICS 238130). OSHA activity number 347026619.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL FRAMERS HL CORP.
- Site address
- 112 HARBOR ROAD
- City
- COLD SPRING HARBOR
- State
- NY
- ZIP
- 11724
- Mailing
- 80 4TH AVENUE, HUNTINGTON STATION, NY 11746
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B05 II
- Issued
- Feb 15, 2024
- Abate by
- Feb 26, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.451(b)(5)(ii):The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a) Worksite: 112 Harbor Road, Cold Spring Harbor, NY 11724 - The employees were performing siding installation while working from a ladder jack scaffold. The scaffold platform extended approximately 5 feet past the support; on or about 10/11/2023. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4839
1926.451 E01
- Issued
- Feb 15, 2024
- Abate by
- Feb 26, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.451(e)(1): Portable ladder, hook-on ladder, attachable ladder, stair tower, stairway-type ladder, ramp, runway, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used to access scaffold platform(s) more than 2 feet above or below a point of access. a) Worksite: 112 Harbor Road, Cold Spring Harbor, NY 11724 - The employees were not protected from falling to the ground approximately 16.5 feet while accessing a ladder jack scaffold using the scaffold support ladders; on or about 10/11/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4839
1926.451 G01 I
- Issued
- Feb 15, 2024
- Abate by
- Feb 26, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) Worksite: 112 Harbor Road, Cold Spring Harbor, NY 11724 - The employees were not protected from falling to the ground approximately 16.5 feet while performing siding installation from a ladder jack scaffold; on or about 10/11/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4839
1926.452 K04
- Issued
- Feb 15, 2024
- Abate by
- Feb 26, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.452(k)(4): Ladders used to support ladder jacks shall be placed, fastened, or equipped with devices to prevent slipping. a) Worksite: 112 Harbor Road, Cold Spring Harbor, NY 11724 - The employees were not protected from falling to the ground approximately 16.5 feet while performing siding installation from a ladder jack scaffold which was not placed, fastened, or equipped with devices to prevent slipping, on or about 10/11/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4839
1926.454 A
- Issued
- Feb 15, 2024
- Abate by
- Feb 26, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.454(a):The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Worksite: 112 Harbor Road, Cold Spring Harbor, NY 11724 - The employees were performing siding installation from a ladder jack scaffold were not trained properly to recognize the hazards associated with the type of scaffold being used and to understand the procedure to control or minimize those hazards; on or about 10/11/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $4839
More inspections in this industry (NAICS 238130)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347026619.