Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: SAUCIER MECHANICAL SERVICES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SAUCIER MECHANICAL SERVICES in 65B MASONIC AVENUE, WALLINGFORD, CT 06492 (NAICS 238220). OSHA activity number 347039216.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Saucier Mechanical Services for free Get an email when a new federal OSHA severe-injury report for Saucier Mechanical Services is published. One employer, no account, unsubscribe in one click.
Site address
65B MASONIC AVENUE
City
WALLINGFORD
State
CT
ZIP
06492
Mailing
148 NORTON STREET, PLANTSVILLE, CT 06479
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
2
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 1, 2023
Abate by
Nov 29, 2023
Penalty
Initial $10,938 · Current $5,469 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  Hawkins Building, first floor: On or about October 17, 2023, the employer did not develop procedures for a lock out/tag out system before employees repaired a hot water pipe located in the hallway ceiling.
Recent events (2)
  • · I (S) $5469
  • · Z (S) $10938

1910.147 C07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 1, 2023
Abate by
Nov 29, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices.  Hawkins Building, first floor: On or about October 17, 2023, the employer did not ensure that employees were given adequate training to understand the need for energy control when repairing what appeared to be a small leak in a hot water pipe located at ceiling level.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347039216.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.