Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TECOMET, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TECOMET, INC. in 5307 95TH AVENUE, KENOSHA, WI 53144 (NAICS 339112). OSHA activity number 347039497.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tecomet, INC. — free Get an email when a new federal OSHA severe-injury report for Tecomet, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TECOMET, INC.
Site address
5307 95TH AVENUE
City
KENOSHA
State
WI
ZIP
53144
Mailing
5307 95TH AVENUE, KENOSHA, WI 53144
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339112
Employees
160
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 25, 2024
Abate by
Feb 21, 2024
Penalty
Initial $10,775 · Current $7,500 Reduced
29 CFR  1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.   (a) On or about October 17, 2023, the employer did not utilize machine specific hazardous energy control procedures for the Jacob Hay Pasteurization machine to clearly and specifically outline the steps for shutting down and isolating the different energy sources. This exposed maintenance employees and passivation employees to pneumatic pressure, chemical pressure release hazards, and amputation hazards from mechanical energy.
Recent events (2)
  • — I (S) $7500
  • — Z (S) $10775

1910.147 C07 I A

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 25, 2024
Abate by
Feb 13, 2024
Penalty
Initial $10,775 · Current $7,500 Reduced
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  (a) On or about October 17, 2023, the employer failed to train and instruct employees who are authorized to perform preventive maintenance and servicing of equipment to the authorized level.  Passivation machine operation employees were trained to the affected employee level, but were tasked to perform filter change procedures that require lockout tagout procedures  to be implemented.
Recent events (2)
  • — I (S) $7500
  • — Z (S) $10775

1910.147 D03

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jan 25, 2024
Abate by
Feb 13, 2024
Penalty
Initial $16,131 · Current $0 Reduced
29 CFR  1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:  (a) On or about October 11, 2023, the employer did not ensure that employees used lockout equipment on the Jacob Hay Pasteurization machine to isolate the electrical and pneumatic energy sources. This exposed passivation employees to chemical pressure hazards, mechanical energy hazards and amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16131

1910.303 B01 IV

Other-than-serious 1 instance 4 exposed
Issued
Jan 25, 2024
Abate by
Feb 6, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation:   (a) On or about  October 17, 2023, the wiring used to power the pump on the Jacob Hay Pasteurization machine had the outer jacket pulled back which exposed the wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Tecomet, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347039497.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.