Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACE HOTEL SWIM CLUB

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACE HOTEL SWIM CLUB in 701 E PALM CANYON DR, PALM SPRINGS, CA 92264 (NAICS 721110). OSHA activity number 347040065.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ACE Hotel Swim Club — free Get an email when a new federal OSHA severe-injury report for ACE Hotel Swim Club is published. One employer, no account, unsubscribe in one click.
Establishment
ACE HOTEL SWIM CLUB
Site address
701 E PALM CANYON DR
City
PALM SPRINGS
State
CA
ZIP
92264
Mailing
701 E PALM CANYON DR, PALM SPRINGS, CA 92264
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
149
Ownership type
A

5 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 16, 2023
Abate by
Jan 5, 2024
Penalty
Initial $5,122 · Current $3,585 Reduced
29 CFR  1910.37(b)(2):  Each exit was not clearly visible and marked by a sign reading "Exit":  Laundry Room: On and/or before October 17, 2023, employees conducted laundry operations where the emergency exit was not marked by a sign reading 'exit' which potentially exposed employees to fire hazards.
Recent events (2)
  • — I (S) $3585.4
  • — Z (S) $5122

1910.37 B05

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 16, 2023
Abate by
Jan 5, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(5):  Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):  Laundry Room: On and/or before October 17, 2023, employees conducted laundry operations where an emergency exit had been changed to no longer serve as an exit for employees working in the space and was not marked by a sign reading 'not an exit' which potentially exposed employees to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 1 2 instances 7 exposed
Issued
Nov 16, 2023
Abate by
Feb 20, 2024
Penalty
Initial $5,122 · Current $3,585 Reduced
29 CFR  1910.151(c):  Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use.  Reference: ANSI Z358.1 Emergency Eyewash and Shower Standard 5.4.2 Reference: The eyewash unit shall be in accessible locations that require no more than 10 seconds to reach, located on the same level as the hazard, and the path of travel shall be free of obstructions that may inhibit the immediate use of the equipment.  Laundry Room and Maintenance Shop: On and/or before October 17, 2023, employees conducted operations using corrosive products in the following areas:  a.  Laundry Room:  Employees used laundry spot pre-treatment cleaner(s) and degreaser(s) without an available eye wash station. b.  Maintenance Shop:  Employees used coil cleaners without an available eye wash station.  Employees were potentially exposed to retinal and corneal burns.
Recent events (2)
  • — I (S) $3585.4
  • — Z (S) $5122

1910.1200 G01

Serious Gravity 1 1 instance 4 exposed
Issued
Nov 16, 2023
Abate by
Jan 5, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  Maintenance Shop:  On and/or before October 17, 2023, employees used corrosive and other hazardous materials where the employer did not have available safety data sheets which potentially exposed employees to retinal and corneal burns.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Other-than-serious 2 instances 4 exposed
Issued
Nov 16, 2023
Abate by
Jan 5, 2024
Penalty
Initial $959 · Current $671 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   Laundry Room and Liquor Storage Room:  On and/or before October 17, 2023,  a. Laundry Room:  the industrial washing machine chemical wall mounted dispenser pump systems were plugged into a relocatable tap for operation purposes which was not used in accordance to manufacturer listing/labeling instructions. b. Liquor Storage Room:  the Excaliber Food Dehydrator was plugged into an outside extension cord for operation purposes which was not used in accordance to manufacturer listing/labeling instructions  These conditions potentially exposed employee(s) to electrical shock and/or fire hazard(s).
Recent events (2)
  • — I (O) $671.3
  • — Z (O) $959

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347040065.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.