2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: THE FIERRO GROUP, LTD. CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE FIERRO GROUP, LTD. CO. in 11255 EASTEX FREEWAY, HOUSTON, TX 77093 (NAICS 332323). OSHA activity number 347041360.

Watch THE Fierro Group, LTD. CO. — free Get an email when a new federal OSHA severe-injury report for THE Fierro Group, LTD. CO. is published. One employer, no account, unsubscribe in one click.
Site address
11255 EASTEX FREEWAY
City
HOUSTON
State
TX
ZIP
77093
Mailing
11255 EASTEX FREEWAY, HOUSTON, TX 77093
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
38
Ownership type
A

5 citations on file for this inspection.

1910.252 B02 III

Other-than-serious Gravity 1 1 instance 38 exposed
Issued
Penalty
Initial $3984.00 · Current $2748.00 Reduced
29 CFR  1910.252(b)(2)(iii):Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  On or about October 18, 2023, at the fabrication shop employees were not protected from rays from welding activities.
Recent events (2)
  • — I (O) $2748
  • — Z (S) $3984

1910.253 B02 IV

Other-than-serious Gravity 5 1 instance 38 exposed
Issued
Penalty
Initial $5313.00 · Current $3626.00 Reduced
29 CFR  1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:   On or about October 18, 2023, at the welding storage area of facility there were two cylinders that did not have a valve caps in place.
Recent events (2)
  • — I (O) $3626
  • — Z (S) $5313

1910.253 B04 I

Other-than-serious Gravity 5 1 instance 38 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.253(b)(4)(i):Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire.  On or about October 18, 2023, at the welding storage area of facility employees were exposed to fire hazards as oxygen and acetylene cylinders were stored next to one another.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 G02 III

Other-than-serious Gravity 5 1 instance 38 exposed
Issued
Penalty
Initial $5313.00 · Current $3626.00 Reduced
29 CFR 1910.305(g)(2)(iii):Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  On or about October 18, 2023, employees were exposed to electrical hazards while using work fans whose strain relief had been damaged.
Recent events (2)
  • — I (O) $3626
  • — Z (S) $5313

1910.334 A02 I

Other-than-serious Gravity 5 1 instance 38 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  On or about October 18, 2023 at the fabrication shop employees were exposed to electrical hazards as there was a work fan that had a frayed cord and were not visually inspected.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347041360.