Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KS ENERGY SERVICES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KS ENERGY SERVICES, LLC in NEAR INTERSECTION OF CARSON PARK DRIVE AND MENOMONIE STREET, EAU CLAIRE, WI 54703 (NAICS 237120). OSHA activity number 347041667.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch KS Energy Services, LLC — free Get an email when a new federal OSHA severe-injury report for KS Energy Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
NEAR INTERSECTION OF CARSON PARK DRIVE AND MENOMONIE STREET
City
EAU CLAIRE
State
WI
ZIP
54703
Mailing
19705 W LINCOLN AVENUE, NEW BERLIN, WI 53146
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
21
Ownership type
A

3 citations on file for this inspection.

1926.652 C02 I

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Jan 5, 2024
Abate by
Jan 29, 2024
Penalty
Initial $5,122 · Current $0 Reduced
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer:  (a) Near the intersection of Menomonie Street and Carson Park Dr., Eau Claire, WI; An Efficiency Production model XLSM-66 4-inch sidewall Municipal Series steel trench shield, used as a cave-in protection system in an excavation up to approximately 5-feet, 10-inches deep, was not used in accordance with the manufacturer's tabulated data and/or limitations, in that plywood Finn Form panels, used as end walls and placed between the steel side panels, were resting directly on the steel spreader pipes that were not designed to withstand side impact/loading.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5122

1926.652 D03

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Jan 5, 2024
Abate by
Jan 29, 2024
Penalty
Initial $0 · Current $5,122
29 CFR 1926.652(d)(3): When material or equipment that was used for protective systems was damaged, a competent person did not examine the material or equipment and evaluate its suitability for continued use:  (a) Near the intersection of Menomonie Street and Carson Park Dr., Eau Claire, WI; An Efficiency Production model XLSM-66 4-inch sidewall Municipal Series steel trench shield, used as a cave-in protection system in an excavation up to approximately 5-feet, 10-inches deep, was placed in service with a damaged side panel that may have compromised the structural integrity of the system.
Recent events (2)
  • — I (O) $5122
  • — Z (S) $0

1926.652 G01 II

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Jan 5, 2024
Abate by
Jan 29, 2024
Penalty
Initial $5,122 · Current $0 Reduced
29 CFR 1926.652(g)(1)(ii): Shields were not installed in a manner to restrict lateral or other hazardous movement of the shield in the event of the application of sudden lateral loads:  (a) Near the intersection of Menomonie Street and Carson Park Dr., Eau Claire, WI; An Efficiency Production model XLSM-66 4-inch sidewall Municipal Series steel trench shield, used as a cave-in protection system in an excavation up to approximately 5-feet, 10-inches deep, was installed in a manner that did not restrict the potential for hazardous movement in that backfilling was not performed along three sides of the shield, presenting gaps ranging from approximately 12-inches to 45-inches between the shielding system and excavation walls.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5122

View KS Energy Services, LLC's full OSHA safety record →