EAU CLAIRE, WI —
OSHA Inspection: KS ENERGY SERVICES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KS ENERGY SERVICES, LLC in NEAR INTERSECTION OF CARSON PARK DRIVE AND MENOMONIE STREET, EAU CLAIRE, WI 54703 (NAICS 237120). OSHA activity number 347041667.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KS ENERGY SERVICES, LLC
- Site address
- NEAR INTERSECTION OF CARSON PARK DRIVE AND MENOMONIE STREET
- City
- EAU CLAIRE
- State
- WI
- ZIP
- 54703
- Mailing
- 19705 W LINCOLN AVENUE, NEW BERLIN, WI 53146
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237120
- Employees
- 21
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.652 C02 I
- Issued
- Jan 5, 2024
- Abate by
- Jan 29, 2024
- Penalty
- Initial $5,122 · Current $0 Reduced
General-duty citation text
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer: (a) Near the intersection of Menomonie Street and Carson Park Dr., Eau Claire, WI; An Efficiency Production model XLSM-66 4-inch sidewall Municipal Series steel trench shield, used as a cave-in protection system in an excavation up to approximately 5-feet, 10-inches deep, was not used in accordance with the manufacturer's tabulated data and/or limitations, in that plywood Finn Form panels, used as end walls and placed between the steel side panels, were resting directly on the steel spreader pipes that were not designed to withstand side impact/loading.
Recent events (2)
- — I (S) $0
- — Z (S) $5122
1926.652 D03
- Issued
- Jan 5, 2024
- Abate by
- Jan 29, 2024
- Penalty
- Initial $0 · Current $5,122
General-duty citation text
29 CFR 1926.652(d)(3): When material or equipment that was used for protective systems was damaged, a competent person did not examine the material or equipment and evaluate its suitability for continued use: (a) Near the intersection of Menomonie Street and Carson Park Dr., Eau Claire, WI; An Efficiency Production model XLSM-66 4-inch sidewall Municipal Series steel trench shield, used as a cave-in protection system in an excavation up to approximately 5-feet, 10-inches deep, was placed in service with a damaged side panel that may have compromised the structural integrity of the system.
Recent events (2)
- — I (O) $5122
- — Z (S) $0
1926.652 G01 II
- Issued
- Jan 5, 2024
- Abate by
- Jan 29, 2024
- Penalty
- Initial $5,122 · Current $0 Reduced
General-duty citation text
29 CFR 1926.652(g)(1)(ii): Shields were not installed in a manner to restrict lateral or other hazardous movement of the shield in the event of the application of sudden lateral loads: (a) Near the intersection of Menomonie Street and Carson Park Dr., Eau Claire, WI; An Efficiency Production model XLSM-66 4-inch sidewall Municipal Series steel trench shield, used as a cave-in protection system in an excavation up to approximately 5-feet, 10-inches deep, was installed in a manner that did not restrict the potential for hazardous movement in that backfilling was not performed along three sides of the shield, presenting gaps ranging from approximately 12-inches to 45-inches between the shielding system and excavation walls.
Recent events (2)
- — I (S) $0
- — Z (S) $5122
More inspections at KS Energy Services, LLC
View KS Energy Services, LLC's full OSHA safety record →
More inspections in this industry (NAICS 237120)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347041667.