Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLORADO CUSTOM STAINLESS INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of COLORADO CUSTOM STAINLESS INC in 3911 INCA STREET, DENVER, CO 80211 (NAICS 332999). OSHA activity number 347045361.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Colorado Custom Stainless INC — free Get an email when a new federal OSHA severe-injury report for Colorado Custom Stainless INC is published. One employer, no account, unsubscribe in one click.
Site address
3911 INCA STREET
City
DENVER
State
CO
ZIP
80211
Mailing
3911 INCA STREET, DENVER, CO 80211
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
6
Ownership type
A

5 citations on file for this inspection.

1910.132 D01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Mar 13, 2024
Abate by
Apr 8, 2024
Penalty
Initial $2,765 · Current $0 Reduced
29 CFR  1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:  (a) Colorado Custom Stainless, 3911 Inca Street, Denver, CO 80211: On or about October 19, 2023, and at times prior, the employer did not determine the appropriate personal protective equipment for the welders and fabricators to wear during normal job activities.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2765

1910.212 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 13, 2024
Abate by
Apr 10, 2024
Penalty
Initial $2,074 · Current $1,244 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Colorado Custom Stainless, 3911 Inca Street, Denver, CO 80211: On or about October 19, 2023, and at times prior, employees were exposed to amputation hazards when operating unguarded DeWalt handheld grinders.
Recent events (2)
  • — I (S) $1244.4
  • — Z (S) $2074

1910.1026 D02 I

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Mar 13, 2024
Abate by
Apr 10, 2024
Penalty
Initial $3,457 · Current $0 Reduced

Hazardous substances 0689

29 CFR  1910.1026(d)(2)(i): The employer using the scheduled monitoring option did not perform initial monitoring to determine the 8-hour time-weighted average exposure to chromium (VI) for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area:  (a) Colorado Custom Stainless, 3911 Inca Street, Denver, CO 80211: On or about October 19, 2023, and at times prior, the employer did not determine employees' exposure to chromium (VI) during daily welding operations. Employees conduct tig arc welding on stainless steel parts on a semi-regular basis. The employer did not determine the 8-hour TWA exposure to the chromium (VI).
Recent events (2)
  • — I (O) $0
  • — Z (S) $3457

1910.1200 E01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Mar 13, 2024
Abate by
Apr 10, 2024
Penalty
Initial $3,457 · Current $0 Reduced

Hazardous substances 0689

29 CFR  1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii)  (a) Colorado Custom Stainless, 3911 Inca Street, Denver, CO 80211: On or about October 19, 2023, and at times prior, the employer had not implemented a written hazard communication program to include information associated with hazards from exposure to hexavalent chromium,  (b) Colorado Custom Stainless, 3911 Inca Street, Denver, CO 80211: On or about October 19, 2023, and at times prior, the employer did not make the written hazard communication program available upon request to the employees or their designated representatives as required in 1910.1200(e)(4).
Recent events (2)
  • — I (O) $0
  • — Z (S) $3457

1910.1200 H01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Mar 13, 2024
Abate by
Apr 10, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 0689

29 CFR  1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) Colorado Custom Stainless, 3911 Inca Street, Denver, CO 80211: On or about October 19, 2023, and at times prior, the employer did not provided training to the welders who conduct tig arc welding on stainless steel on exposure to Cr(VI) or how to protect themselves against exposure while conducting their normal job activities.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347045361.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.