SAN ANTONIO, TX ·
OSHA Inspection: PEAK TRAILER GROUP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PEAK TRAILER GROUP in 1605 ACKERMAN ROAD, SAN ANTONIO, TX 78219 (NAICS 423120). OSHA activity number 347053084.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PEAK TRAILER GROUP
- Site address
- 1605 ACKERMAN ROAD
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78219
- Mailing
- 1605 ACKERMAN ROAD, SAN ANTONIO, TX 78219
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423120
- Employees
- 52
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.184 C01
- Issued
- Jan 4, 2024
- Penalty
- Initial $6,026 · Current $3,616 Reduced
General-duty citation text
29 CFR 1910.184(c)(1): Sling(s) that were damaged or defective were used: Shop Bay: On or about October 23, 2023, and times prior thereto, employees were exposed struck-by hazards by utilizing a damaged sling used to lift material and parts.
Recent events (2)
- · I (S) $3615.6
- · Z (S) $6026
1910.334 A02 I
- Issued
- Jan 4, 2024
- Penalty
- Initial $1,128 · Current $677 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): Parts Bay: On or about October 23, 2023, and times prior thereto, employees were exposed to electrical hazards due to a damaged extension cord connected to a portable fan.
Recent events (2)
- · I (O) $676.8
- · Z (O) $1128
More inspections in this industry (NAICS 423120)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347053084.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.