FRANKSVILLE, WI —
OSHA Inspection: ECHO LAKE FOODS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ECHO LAKE FOODS, INC. in 2319 RAYMOND AVENUE, FRANKSVILLE, WI 53126 (NAICS 311412). OSHA activity number 347057408.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ECHO LAKE FOODS, INC.
- Site address
- 2319 RAYMOND AVENUE
- City
- FRANKSVILLE
- State
- WI
- ZIP
- 53126
- Mailing
- P.O. BOX 279 ATTN: MARCI DRENSEK, BURLINGTON, WI 53105
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311412
- Employees
- 192
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.119 D03 I B
- Issued
- Mar 22, 2024
- Abate by
- May 20, 2024
- Penalty
- Initial $5,876 · Current $5,876
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): The employer's piping and instrument diagrams were not accurate and did not represent equipment that was existing and was part of the process. (a) On or about October 25, 2023, inspection of the North Ammonia Refrigeration Engine Room, identified that P&IDs did not reflect current piping configuration associated with LSS line. The LSS line was labeled as LTSR. (b) On or about October 25, 2023, inspection of the North Ammonia Refrigeration Engine Room, identified that P&IDs did not reflect current piping configuration associated with pressure relief valve connecting C-10 oil cooler to C-10 Oil separator. The valve was marked as TWG valve. (c) On or about October 25, 2023, inspection of the North Ammonia Refrigeration Engine Room, identified that P&IDs did not reflect current piping configuration in that the valve was not labeled or identified on the P&ID.
Recent events (2)
- — I (S) $5876
- — Z (S) $5876
1910.119 J05
- Issued
- Mar 22, 2024
- Abate by
- May 8, 2024
- Penalty
- Initial $16,131 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that were outside acceptable limits (defined by the process safety information on paragraph (d) of this section) before use. (a) On or about October 25, 2023, a Cyrus Shank pressure relief valve ( (75 psig) that connected the oil cooler and oil separator on Compressor C-10 was beyond the five year manufacture required replacement date. The pressure relief valve was installed in December of 2011, and was past the required replacement date by six years.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
1910.119 L01
- Issued
- Mar 22, 2024
- Abate by
- May 8, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(l)(1): The employer did not establish or implement written procedures to manage changes to process chemicals, technology, equipment, and procedures, and changes to facilities that affect a covered process. (a) On or about October 25, 2023, a management of change (MOC) was not implemented for Cyrus Shank pressure relief valve that connected the oil cooler and oil separator on Compressor C-10 that was beyond the five year manufacture required replacement date. The Cyrus Shank pressure relief valve (75 psig) was installed in December of 2011, was past the required replacement date by 6 years. (b) On or about October 25, 2023, a management of change ((MOC) - 52) was not completed before commencement of installation of new spiral freezer in the North Ammonia Refrigeration Engine Room. The employer commenced work on the new spiral freezer for the north ammonia system without the completion of MOC-52. The work commenced on June 2023 and the MOC was not completed till October 2, 2023. (c) On or about October 25, 2023, a management of change was not initiated and completed before commencement of installation of coil addition for the new spiral freezer in the North Ammonia Refrigeration Engine Room. The employer commenced work on the new coil addition for the north ammonia system without the initiation of MOC-53.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Echo Lake Foods, INC.
View Echo Lake Foods, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311412)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347057408.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.