OSHA Inspection: STOUT CONSTRUCTION, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STOUT CONSTRUCTION, LLC in E6091 578TH AVE., MENOMONIE, WI 54751 (NAICS 238910). OSHA activity number 347057705.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stout Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Stout Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
E6091 578TH AVE.
City
MENOMONIE
State
WI
ZIP
54751
Mailing
614 25TH STREET, CHETEK, WI 54728
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.652 C02 III

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jan 19, 2024
Abate by
Feb 9, 2024
Penalty
Initial $11,292 · Current $0 Reduced
29 CFR 1926.652(c)(2)(iii): Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations were not in written form at the jobsite during construction of the protective system and thereafter until the protective system was no longer utilized:  (a) Sewer main excavation; An Empire Manufacturing brand model no. 8HC-822 shield system, was constructed and used as a cave-in protective system in an excavation with maximum depths ranging between 22-feet to 24-feet, without the manufacturer's tabulated data available on site.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11292

1926.652 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 19, 2024
Abate by
Feb 9, 2024
Penalty
Initial $0 · Current $7,904
29 CFR 1926.652(c)(4)(i): Support systems, shield systems, and other protective systems not utilizing Option 1, Option 2 or Option 3, above, were not approved by a registered professional engineer:   (a) Sewer main excavation; An Empire Manufacturing brand model no. 8HC-822 shield system, used as a cave-in protective system in an excavation with maximum depths ranging between 22-feet to 24-feet, was not approved by a registered professional engineer.
Recent events (2)
  • — I (S) $7904.4
  • — Z (S) $0

1926.652 G02

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Jan 19, 2024
Abate by
Feb 9, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.652(g)(2): Excavation of earth material to a level greater than 2 feet (.61m) below the bottom of a shield was permitted:  (a) Sewer main excavation; Earth material was excavated to a depth of up to four feet below the bottom of an Empire Manufacturing brand model no. 8HC-822 shield system, used as a cave-in protective system in an excavation with maximum depths ranging between 22-feet to 24-feet.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.1053 B01

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Jan 19, 2024
Abate by
Feb 9, 2024
Penalty
Initial $4,113 · Current $0 Reduced
29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:  (a) Sewer main excavation; A Louisville brand model FE3112, 12-foot fiberglass straight ladder, placed against the top spreader of an Empire Manufacturing brand model no. 8HC-822 shield system and used by employees to enter and exit the shield, did not extend at least 3-feet above the spreader and was not secured to prevent displacement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4113