Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FONTRICK DOOR, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FONTRICK DOOR, INC. in 9 APOLLO DRIVE, BATAVIA, NY 14020 (NAICS 321911). OSHA activity number 347059842.

Watch Fontrick Door, INC. — free Get an email when a new federal OSHA severe-injury report for Fontrick Door, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FONTRICK DOOR, INC.
Site address
9 APOLLO DRIVE
City
BATAVIA
State
NY
ZIP
14020
Mailing
9 APOLLO DRIVE, BATAVIA, NY 14020
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
16
Ownership type
A

6 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3134.00 · Current $1890.00 Reduced
29 CFR  1910.22(a)(1): Places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition: a) Throughout work area - On or about 10/25/23, the floors throughout the workplace were covered in wood dust.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1890
  • — Z (S) $3134

1910.107 G02

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3134.00 · Current $1890.00 Reduced
29 CFR  1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:  a) Finishing Department - On or about 10/25/23, the walls and the ceiling of the spray booth were covered in thick deposits of paint residue. Employees spray combustibles materials such as, but not limited to Kilz 2 All Purpose Interior/Exterior Primer, a flammable liquid with a flash point of 74 deg. F.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1890
  • — Z (S) $3134

1910.157 C01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3134.00 · Current $1890.00 Reduced
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a)Throughout facility - On or about 10/25/23, portable fire extinguishers were blocked and not available for immediate use by employees.
Recent events (2)
  • — I (S) $1890
  • — Z (S) $3134

1910.305 G01 IV B

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2350.00 · Current $1440.00 Reduced
29 CFR  1910.305(g)(1)(iv)(B):Flexible cords and cables may not be used where run through holes in walls, ceilings or floors:  a) Finishing Department - On or about 10/25/23, an extension cord, used to power the drill used for mixing paint and the Titan 440 Airless Spray System, was run through a hole in the wall and then plugged into an outlet on the opposite side of the wall.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2350

1910.1200 E01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3134.00 · Current $1890.00 Reduced
29 CFR  1910.1200(e)(1):The employer did not develop, implement and maintain at the workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g) and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met: a) Throughout Facility - On or about 10/25/23, the employer's written hazard communication program did not describe how the criteria for paragraph (h) employee information and training will be met. Employees work with materials such as, but not limited to,  Kilz 2 All Purpose Interior/Exterior Primer (containing calcium carbonate, petroleum distillates, and mineral spirits), Evercoat Liteweight Non Clog lightweight filler (containing styrene, acid anhydride, and titanium dioxide), and Evercoat Cream Hardener (containing dibenzoyl peroxide, zinc stearate, and calcium sulfate).  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1890
  • — Z (S) $3134

1910.1200 H01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area.   a) Throughout Facility - On or about 10/25/23, employees who works with materials such as, but not limited to,  Kilz 2 All Purpose Interior/Exterior Primer (containing calcium carbonate, petroleum distillates, and mineral spirits), Evercoat Liteweight Non Clog lightweight filler (containing styrene, acid anhydride, and titanium dioxide), and Evercoat Cream Hardener (containing dibenzoyl peroxide, zinc stearate, and calcium sulfate) were not provided with information and training on the hazardous materials that they work with.  Employees shall be informed of the following:  1) The requirements of this section; 2) Any operations where hazardous chemicals are present; AND 3) The location and availability of the written Hazard Communication Program, list(s) of hazardous chemicals, and Safety      Data Sheets.  Employee training shall include at least:  1) Methods and observations that may be used to detect the presence or release of a hazardous chemical in the      work area. 2) The physical and health hazards of the chemicals in the work area. 3) The measures employees can take to protect themselves such as specific procedures, appropriate work practices,     emergency procedures and personal protective equipment to be used. 4) The details of the employers Hazard Communication Program including an explanation of labeling systems, Safety      Data Sheets, and how employees can obtain and use the appropriate hazard information.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View FONTRICK DOOR, INC.'s full OSHA safety record →