Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ABSOLUTE ROOFING SOLUTIONS, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ABSOLUTE ROOFING SOLUTIONS, LLC in 2450 W. PERSHING BLVD, NORTH LITTLE ROCK, AR 72114 (NAICS 238160). OSHA activity number 347059875.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Absolute Roofing Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Absolute Roofing Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2450 W. PERSHING BLVD
City
NORTH LITTLE ROCK
State
AR
ZIP
72114
Mailing
12424 NORWICH ST, FORT SMITH, AR 72904
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
21
Ownership type
A

6 citations on file for this inspection.

1903.19 C01

Other-than-serious 4 instances 1 exposed
Issued
Jan 16, 2025
Abate by
Feb 21, 2025
Penalty
Initial $531 · Current $531
29 CFR  1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  a) On or about January 16, 2025, the employer failed to submit certification of corrective action for Citation 1, Item 1, issued on April 15, 2024, with an abatement due date of May 9, 2024.  b) On or about January 16, 2025, the employer failed to submit certification of corrective action for Citation 1, Item 2, issued on April 15, 2024, with an abatement due date of May 9, 2024.  c) On or about January 16, 2025, the employer failed to submit certification of corrective action for Citation 1, Item 3, Group a, issued on April 15, 2024, with an abatement due date of May 9, 2024.  d) On or about January 16, 2025, the employer failed to submit certification of corrective action for Citation 1, Item 3, Group b, issued on April 15, 2024, with an abatement due date of May 9, 2024.
Recent events (1)
  • — Z (O) $531

1903.19 D01

Other-than-serious 1 instance 1 exposed
Issued
Jan 16, 2025
Abate by
Feb 21, 2025
Penalty
Initial $531 · Current $531
29 CFR  1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:   On or about January 16, 2025, the employer failed to submit documentation and certification of corrective action for Citation 1, Item 2, issued on April 15, 2024, with an abatement due date of May 9, 2024.
Recent events (1)
  • — Z (O) $531

1926.102 A01

Serious Gravity 5 1 instance 20 exposed
Issued
Apr 15, 2024
Abate by
May 9, 2024
Penalty
Initial $3,687 · Current $3,687
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:   On or about October 25, 2023, employees performing roofing work using an air powered nail gun were not using eye protection.
Recent events (1)
  • — Z (S) $3687

1926.501 B13

Serious Gravity 10 3 instances 20 exposed
Issued
Apr 15, 2024
Abate by
May 9, 2024
Penalty
Initial $6,452 · Current $6,452
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    On or about October 25, 2023, employees were performing roofing activities such as, but not limited to installing underlayment, shingles, and flashing at heights greater than 6-feet, without fall protection on the following:  a) Building 2512;  b) Building 2524;  c) Building 2532.
Recent events (1)
  • — Z (S) $6452

1926.1053 B01

Serious Gravity 5 2 instances 8 exposed
Issued
Apr 15, 2024
Abate by
May 9, 2024
Penalty
Initial $4,610 · Current $4,610
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  On or about October 25, 2023, employees were performing roofing activities such as, but not limited to installing underlayment, shingles, and flashing at heights greater than 6-feet, where the following:  a) On Building 2512 - ladders to access the roof from the ground level side rails did not extend 3-feet above the roof surface;  b) On Building 2524 - ladders to access the roof from the ground level side rails did not extend 3-feet above the roof surface.
Recent events (1)
  • — Z (S) $4610

1926.1053 B05 I

Serious Gravity 5 3 instances 20 exposed
Issued
Apr 15, 2024
Abate by
May 9, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support):   On or about October 25, 2023, employees were performing roofing activities such as, but not limited to installing underlayment, shingles, and flashing at heights greater than 6-feet where the following:   a) On Building 2512 used a ladder to access the roof from the ground level where the ladder was placed at angles less than 75 degrees.  b) On Building 2524 used a ladder to access the roof from the ground level where the ladder was placed at angles less than 75 degrees.  c) On Building 2532 used a ladder to access the roof from the ground level where the ladder was placed at angles less than 75 degrees.