Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PINNACLE STRUCTURES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PINNACLE STRUCTURES, INC. in 2665 BILL FOSTER MEMORIAL HWY, CABOT, AR 72023 (NAICS 332311). OSHA activity number 347069023.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pinnacle Structures, INC. — free Get an email when a new federal OSHA severe-injury report for Pinnacle Structures, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2665 BILL FOSTER MEMORIAL HWY
City
CABOT
State
AR
ZIP
72023
Mailing
P O BOX 1268, CABOT, AR 72023
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
150
Ownership type
A

6 citations on file for this inspection.

1910.107 B05 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 27, 2024
Abate by
Jul 15, 2024
Penalty
Initial $8,296 · Current $4,978 Reduced
29 CFR 1910.107(b)(5)(iv):  Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:  On or about November 14, 2023, at the dry filter-equipped spray booth, employees were required to spray paint steel structure building components such as, but not limited to, beams, girders, columns, arms, angles, and rods with paints that contained flammable solvents (ethyl benzene and xylene).  The spray booth was not equipped with an automatic fire suppression system (sprinklers).
Recent events (3)
  • — P (S) $4977.6
  • — I (S) $4977.6
  • — Z (S) $8296

1910.107 B06

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 27, 2024
Abate by
May 13, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(6):  Spray booth(s)�having a�frontal area�larger than�9 square�feet did�not have�metal deflectors�or curtains�not less�than 2�1/2 inches�deep installed�at the�upper outer�edge of�the booth�over the�opening:   On or about November 14, 2023, at the spray booth, employees were painting parts such as but not limited to columns, beams and other structural steel parts, a deflector was not provided at the top of the opening.   The spray booth frontal opening was approximately 50-foot wide.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G02

Serious Gravity 5 2 instances 3 exposed
Issued
Mar 27, 2024
Abate by
May 13, 2024
Penalty
Initial $8,296 · Current $4,978 Reduced
29 CFR 1910.107(g)(2):  All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:  On or about November 14, 2023, employees spraying paint onto structural steel pieces where: a)  The spray paint booth had visible accumulations of overspray on the surfaces. b)  The spraying area had visible accumulations of overspray on the floor, supports, and along the wall behind the small parts paint table.
Recent events (2)
  • — I (S) $4977.6
  • — Z (S) $8296

1910.134 D01 III

Other-than-serious 1 instance 3 exposed
Issued
Mar 27, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 10802590

29 CFR 1910.134(d)(1)(iii):  The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  On or about November 14, 2023, employees spraying paint onto structural steel pieces such as beams, columns, purlins, and joists that contained 24% xylene and 5% ethyl benzene.   The employer did not evaluate employee exposure levels: a)  in the spray paint booth b)  in spray paint area
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K06

Other-than-serious 1 instance 3 exposed
Issued
Mar 27, 2024
Abate by
Apr 22, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 10802590

29 CFR 1910.134(k)(6):  The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:   On or about October 14, 2023, in the spray paint booth and spray paint area employees spray paint containing 24% xylene and 5% ethyl benzene onto structural steel pieces such as beams, columns, purlins, and joists.  The employer did not provide information contained in Appendix D.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 G01 I A

Other-than-serious 1 instance 1 exposed
Issued
Mar 27, 2024
Abate by
Apr 22, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 10802590

29 CFR 1910.134(g)(1)(i)(A):  Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:    On or about October 14, 2023, in the spray paint booth and spray paint area, painters were observed to have a full beard while wearing a 3M model 8511 N95 respirator.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Pinnacle Structures, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347069023.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.