Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MANUEL GONZALEZ

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of MANUEL GONZALEZ in 1706 KUALA DR, WENTZVILLE, MO 63385 (NAICS 238160). OSHA activity number 347070880.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Manuel Gonzalez — free Get an email when a new federal OSHA severe-injury report for Manuel Gonzalez is published. One employer, no account, unsubscribe in one click.
Establishment
MANUEL GONZALEZ
Site address
1706 KUALA DR
City
WENTZVILLE
State
MO
ZIP
63385
Mailing
4527 STIVERS ST., SAINT LOUIS, MO 63114
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 13, 2023
Penalty
Initial $4,465 · Current $4,465
29 CFR  1926.102(a)(1): Employees did not use eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  On or about 10/31/2023, the employer did not protect employees who were exposed to struck-by hazards due to using pneumatic nail guns without the use of eye protection at a residential roofing job site located at 1706 Kuala Dr., Wentzville, MO.
Recent events (1)
  • — Z (S) $4465

1926.501 B13

Serious Gravity 10 1 instance 7 exposed
Issued
Dec 13, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  On or about 10/31/2023, the employer did not protect employees who were engaged in residential roofing operations 6ft (1.8m) or more above lower levels while at the job site located at 1706 Kuala Dr., Wentzville, MO. The employees were conducting residential roofing operations and were exposed to the hazard of falling approximately twelve (12) feet.
Recent events (1)
  • — Z (S) $6250

View Manuel Gonzalez's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347070880.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.