Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J AND G WALLS SYSTEMS INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J AND G WALLS SYSTEMS INC in RIO LIMPION LN, NOKOMIS, FL 34274 (NAICS 238140). OSHA activity number 347075780.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J and G Walls Systems INC — free Get an email when a new federal OSHA severe-injury report for J and G Walls Systems INC is published. One employer, no account, unsubscribe in one click.
Site address
RIO LIMPION LN
City
NOKOMIS
State
FL
ZIP
34274
Mailing
314 ALMA STREET, KISSIMMEE, FL 34741
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.502 D15

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 22, 2023
Abate by
Jan 22, 2024
Penalty
Initial $3,349 · Current $3,349
29 CFR  1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.   a) At the work site located at Rio Limpion Ln, Nokomis, Florida: On or about November 1, 2023, subcontracted employees were exposed to a fall hazard, in that, employees engaged in roofing activities were using temporary anchor points that were not properly installed according to the manufacturers installation instructions.
Recent events (1)
  • — Z (S) $3349

1926.502 D06 II

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 22, 2023
Abate by
Jan 22, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(6)(ii): A snaphook not of the locking type and not designed to be connected to one another were engaged to each other.   a) At the work site located at Rio Limpion Ln, Nokomis, Florida: On or about November 1, 2023, subcontracted employees were exposed to a fall hazard of 51-ft to the lower level, in that, the fall protection system provided was not installed as intended by the manufacturer as the self retracting life-line used was attached to a free-fall lanyard and not to the anchor, while engaged in siding work on a 8:12 roof.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347075780.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.