Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MONITOR CANOPIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MONITOR CANOPIES, INC. in 200 ELLIOT ROAD, SHERMAN, TX 75092 (NAICS 332999). OSHA activity number 347079428.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Monitor Canopies, INC. — free Get an email when a new federal OSHA severe-injury report for Monitor Canopies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
200 ELLIOT ROAD
City
SHERMAN
State
TX
ZIP
75092
Mailing
200 ELLIOT ROAD, SHERMAN, TX 75092
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
18
Ownership type
A

12 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 3 instances 18 exposed
Issued
Nov 10, 2023
Penalty
Initial $3,036 · Current $1,822 Reduced
29 CFR  1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:   On November 1, 2023, and times prior thereto, the employer did not ensure exit doors were unlocked in the production and maintenance shops to provide quick exit of the building in case of an emergency exposing employees to fire and smoke hazards.  a) Exit door in the maintenance shop lock during business hours, b) Exit door lock , south side production shop when occupied by employees. c)  Exit door lock, west side production shop when occupied by employees.
Recent events (2)
  • — I (S) $1821.6
  • — Z (S) $3036

1910.37 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 10, 2023
Penalty
Initial $2,277 · Current $1,366 Reduced
29 CFR  1910.37(b)(2):Each exit was not clearly visible and marked by a sign reading "Exit".  On November 1, 2023, and times prior thereto, the employer did not ensure each exit door was equipped with an EXIT sign exposing employees to entrapment hazards.
Recent events (2)
  • — I (S) $1366.2
  • — Z (S) $2277

1910.178 L04 III

Serious Gravity 5 1 instance 18 exposed
Issued
Nov 10, 2023
Abate by
Dec 11, 2023
Penalty
Initial $3,572 · Current $2,143 Reduced
29 CFR  1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  On November 1, 2023, and times prior thereto, the employer did not ensure powered industrial truck operators were provided training and recertification as required every three years exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $2143.2
  • — Z (S) $3572

1910.178 L06

Serious Gravity 5 1 instance 18 exposed
Issued
Nov 10, 2023
Abate by
Dec 11, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):   On November 1, 2023, and times prior thereto, operators of the Yale forklifts were not trained and certified as required to operate the equipment exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 IV F

Serious Gravity 5 2 instances 18 exposed
Issued
Nov 10, 2023
Penalty
Initial $3,036 · Current $1,822 Reduced
29 CFR  1910.212(a)(3)(iv)(f): The point of operation of power saws whose operation exposed an employee to injury were not guarded:   On November 1, 2023, and times prior thereto, in the production shop, employees operating chop saws with the guards missing and/or broken that did not completely enclose the blade were exposed to cuts, abrasion and amputation hazards.  a) North side, in the production shop, the Pro-tech cut off saw was used with broken guard, b) South west side of the production shop Brilliant metal cut off saw missing guard.
Recent events (2)
  • — I (S) $1821.6
  • — Z (S) $3036

1910.253 B02 II

Serious Gravity 1 1 instance 18 exposed
Issued
Nov 10, 2023
Penalty
Initial $2,277 · Current $1,366 Reduced
29 CFR  1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons.   On November 1, 2023, and times prior thereto, inside the welding shop, an Argon compressed cylinder was not chained or secured from falling exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $1366.2
  • — Z (S) $2277

1904.32 B03

Other-than-serious 4 instances 18 exposed
Issued
Nov 10, 2023
Abate by
Dec 11, 2023
Penalty
Initial $893 · Current $536 Reduced
29 CFR  1904.32(b)(3): The person who certified the annual summary was not a company executive as defined in 29 CFR 1904.32(b)(4):   On November 1, 2023, and times prior thereto, an outside consultant that was not a company executive signed and certified the employer's annual summaries.  a) 2019 summary was not signed by the owner or an executive company representative, a) 2020 summary was not signed by the owner or an executive company representative, a) 2021 summary was not signed by the owner or an executive company representative, a) 2022 summary was not signed by the owner or an executive company representative.
Recent events (2)
  • — I (O) $535.8
  • — Z (O) $893

1904.32 B06

Other-than-serious 4 instances 18 exposed
Issued
Nov 10, 2023
Abate by
Dec 11, 2023
Penalty
Initial $0 · Current $0
29 CFR  1904.32(b)(6): 29 CFR 1904.32(b)(6) The annual summary was not posted no later than February 1 of the year following the year covered by the records, and kept in place until April 30"   On November 1, 2023, and times prior thereto, the employer had not been posting the annual OSHA 300A logs as required by the OSHA regulations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L01 I

Other-than-serious 1 instance 18 exposed
Issued
Nov 10, 2023
Abate by
Dec 11, 2023
Penalty
Initial $501 · Current $301 Reduced
29 CFR  1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):   On November 1, 2023, and times prior thereto, the employer failed to ensure forklift operators were competent to operate forklifts by training and guidance by the trainer exposing employees to struck-by hazards.
Recent events (2)
  • — I (O) $300.6
  • — Z (O) $501

1910.178 Q07

Other-than-serious 1 instance 18 exposed
Issued
Nov 10, 2023
Abate by
Dec 11, 2023
Penalty
Initial $501 · Current $301 Reduced
29 CFR  1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift.   On November 1, 2023, and times prior thereto, the employer did not ensure daily inspections on the Yale industrial trucks were conducted, exposing employees to struck-by hazards.
Recent events (2)
  • — I (O) $300.6
  • — Z (O) $501

1910.303 B01 IV

Other-than-serious 1 instance 3 exposed
Issued
Nov 10, 2023
Penalty
Initial $426 · Current $256 Reduced
29 CFR  1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation:   On November 1, 2023, and times prior thereto, at the trim break machine on the wall, an outlet box with exposing wiring missing cover plate exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $255.6
  • — Z (O) $426

1910.305 B01

Other-than-serious 2 instances 18 exposed
Issued
Nov 10, 2023
Penalty
Initial $426 · Current $256 Reduced
29 CFR 1910.305(b)(1): Openings through which conductors enter boxes, cabinets, or fittings were not effectively closed:   On November 1, 2023, and times prior thereto, the employer did not place knockout plugs where electrical outlets and machine electrical boxes energizes lights and machine.  a)  On the south side of the production shop, knockouts missing from power box that energize a wall fan, b)  On the south west side of the production shop, at the Peddinghaus machine, the power box was missing knockouts.
Recent events (2)
  • — I (O) $255.6
  • — Z (O) $426

View Monitor Canopies, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347079428.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.