Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELECTRIC EEL MANUFACTURING CO., INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ELECTRIC EEL MANUFACTURING CO., INC. in 501 LEFFEL LN, SPRINGFIELD, OH 45503 (NAICS 423720). OSHA activity number 347081630.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Electric EEL Manufacturing CO., INC. — free Get an email when a new federal OSHA severe-injury report for Electric EEL Manufacturing CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
501 LEFFEL LN
City
SPRINGFIELD
State
OH
ZIP
45503
Mailing
501 LEFFEL LN, SPRINGFIELD, OH 45503
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423720
Employees
39
Ownership type
A

1 citation on file for this inspection.

1910.212 A01

Serious Gravity 10 3 instances 3 exposed
Issued
Mar 1, 2024
Abate by
Mar 27, 2024
Penalty
Initial $11,292 · Current $3,500 Reduced
29 CFR  1910.212(a)(1):Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  a) On or about 11/03/2023, employer did not ensure that employees operating a JET 15" Bench Drill Press: Model J-2500 (SN:21077947) to debur parts for cables had guarding to prevent exposure to the rotating drill capable of spinning up to 1720 RPM.  b) On or about 11/03/2023, employer did not ensure that employees operating a JET 15" Bench Drill Press: Model J-2530(SN:23058003) to debur parts for cables had guarding to prevent exposure to the rotating drill capable of spinning up to 1720 RPM.  c) On or about 11/03/2023, employer did not ensure that a Colonial Junior Press: Nomenclature M53(SN:G-3231) had adequate guarding to prevent employees from reaching over, under, and around the barrier guard, while the press pushes down to makes a keyway for a sprocket that is installed into a gearbox for Electric Eel's sectional drain cleaners creating a pinch point hazard.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $11292

View Electric EEL Manufacturing CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347081630.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.