OSHA Inspection: TAMIAMI BUILDERS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TAMIAMI BUILDERS INC. in 900 INDUSTRIAL BLVD, NAPLES, FL 34104 (NAICS 238160). OSHA activity number 347081903.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tamiami Builders INC. — free Get an email when a new federal OSHA severe-injury report for Tamiami Builders INC. is published. One employer, no account, unsubscribe in one click.
Site address
900 INDUSTRIAL BLVD
City
NAPLES
State
FL
ZIP
34104
Mailing
3500 RADIO ROAD UNIT A, NAPLES, FL 34104
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

1 citation on file for this inspection.

1926.501 B10

Serious Gravity 10 2 instances 3 exposed
Issued
Apr 22, 2024
Abate by
May 2, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.501(b)(10):Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:  On or about 10/30/2023 and at times prior, at the worksite located at 900 Industrial Blvd, Naples Florida 34104,  (a) At the middle building, employees were exposed to a 15.1-foot fall hazard while replacing a corrugated metal roof.  (b) At the north building, employees were exposed to a 20-foot fall hazard while replacing a corrugated metal roof.  In the alternative:  29 CFR  1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems:   On or about 10/30/2023 and at times prior, at the worksite located at 900 Industrial Blvd, Naples Florida 34104,  (a) At the middle building, employees were exposed to a 15.1-foot fall hazard while replacing a corrugated metal roof.  (b) At the north building, employees were exposed to a 20 foot fall hazard while  replacing a corrugated metal roof.
Recent events (1)
  • — Z (S) $4839

View Tamiami Builders INC.'s full OSHA safety record →