OSHA Inspection: DALTILE

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DALTILE in 12001 RAILROAD DRIVE, EL PASO, TX 79934 (NAICS 327991). OSHA activity number 347083677.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Daltile — free Get an email when a new federal OSHA severe-injury report for Daltile is published. One employer, no account, unsubscribe in one click.
Establishment
DALTILE
Site address
12001 RAILROAD DRIVE
City
EL PASO
State
TX
ZIP
79934
Mailing
12001 RAILROAD DRIVE, EL PASO, TX 79934
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
268
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II B

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Mar 8, 2024
Abate by
Mar 27, 2024
Penalty
Initial $16,131 · Current $0 Reduced
29 CFR  1910.147(c)(4)(ii)(B): The energy control procedure did not clearly specificity procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:   On or about November 1, 2023, the employer did not develop procedural steps for the removal of defective tile from the conveyor belt. This condition exposed employee to caught-between hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $16131
  • — Z (S) $16131

1910.261 L02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Mar 8, 2024
Abate by
Apr 3, 2024
Penalty
Initial $13,828 · Current $0 Reduced
29 CFR  1910.261(l)(2): Emergency stops. Electrically or manually operated quick power disconnecting devices, interlocked with braking action, were not provided on all operating sides of the machine within easy reach of all employees.   On or about November 1, 2023, employer did not ensure to install an emergency stop button on conveyor belt. This condition exposed employee to caught between hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $13828
  • — Z (S) $13828

View Daltile's full OSHA safety record →