Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRESTIGE MARBLE & GRANITE INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRESTIGE MARBLE & GRANITE INC. in 702 BROAD ST., EMMAUS, PA 18049 (NAICS 327991). OSHA activity number 347084246.

Watch Prestige Marble & Granite INC. — free Get an email when a new federal OSHA severe-injury report for Prestige Marble & Granite INC. is published. One employer, no account, unsubscribe in one click.
Site address
702 BROAD ST.
City
EMMAUS
State
PA
ZIP
18049
Mailing
133 STATE AVENUE, EMMAUS, PA 18049
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
24
Ownership type
A

8 citations on file for this inspection.

1910.132 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 6, 2024
Abate by
May 13, 2024
Penalty
Initial $6,453 · Current $3,869 Reduced
29 CFR  1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):   a)  Production Area - On or about November 6, 2023, Employees perform tasks in a production shop where there is a danger of falling or rolling objects and produces flying particles.  The employer has not accessed the workplace to determine if personal protective equipment is necessary.
Recent events (2)
  • — I (S) $3869
  • — Z (S) $6453

1910.133 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 6, 2024
Abate by
May 13, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.133(a)(1):Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:  a)  Production Area - On or about November 6, 2023, Employees perform tasks in a production shop that produces flying particles.  The employer has not required that employees utilize any means of eye protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.136 A

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 6, 2024
Abate by
May 13, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.136(a):The employer did not ensure that each affected employee used protective footwear when working in areas where there was a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet were exposed to electrical hazards:  a)  Production Area - On or about November 6, 2023, Employees perform tasks in a production shop where there is a danger of falling or rolling objects.  The employer did not ensure that each affected employee utilized protective footwear.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 6, 2024
Abate by
May 13, 2024
Penalty
Initial $8,067 · Current $4,839 Reduced
29 CFR  1910.178(l)(1)(ii):The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck.  a) Shop Area - On or about November 6, 2023, employees are assigned to operate powered industrial trucks, but the employer has not ensured that each operator has completed required training.
Recent events (2)
  • — I (S) $4839
  • — Z (S) $8067

1910.303 B07 I

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 6, 2024
Abate by
May 13, 2024
Penalty
Initial $4,839 · Current $2,423 Reduced
29 CFR  1910.303(b)(7)(i):Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.  a)  Shop Area - On or about November 6, 2023, On the North wall of the shop area, near the entrance door to an office, an electrical distribution panel contains openings that are not effectively closed, exposing employees to shock hazards.
Recent events (2)
  • — I (S) $2423
  • — Z (S) $4839

1910.305 G01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 6, 2024
Abate by
May 13, 2024
Penalty
Initial $6,453 · Current $3,869 Reduced
29 CFR  1910.305(g)(1)(i):Flexible cords and cables were not approved for conditions of use and location:  a)  Sink Fabrication area - On or about November 6, 2023, employees were performing tasks associated with wet saw cutting of manufactured solid surface countertop material.  Electrical cords were in contact with airborne and standing water but were not rated for wet location use.
Recent events (2)
  • — I (S) $3869
  • — Z (S) $6453

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Mar 6, 2024
Abate by
May 13, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)  production Shop, Break Area - On or about November 6, 2023, The shop area has a refrigerator for employee use near the restroom.  The refrigerator has its power cord connected electrically to a relocatable power tap, along with a hot glue gun and an employee's cell phone charger.  The power tap is not listed or labeled for the electrical load of these devices.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 3 instances 3 exposed
Issued
Mar 6, 2024
Abate by
May 13, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Shop Area - On or about November 6, 2023, Flexible electrical extension cords were used as substitutes for permanent structure wiring.  A 35' green electrical extension cord was secured to a bean clap attached to a building column, suspended by tie wire, daisey chained to another extension cord in an effort to provide power to another portion of the shop area.  b) Shop Area - On or about November 6, 2023, Flexible electrical extension cords were used as substitutes for permanent structure wiring.  A length of SJ cord was hard wired to a junction box at ceiling height and run down to a usable height.   Building members were as support along with being zip tied to a length of wire rope.  c) Shop Area- On or about November 6, 2023, Flexible electrical extension cords were used as substitutes for permanent structure wiring.   An extension cord is electrically connected to an outlet next to the South exit door.  The cord is zip tied several times to electrical conduit that extends into another portion of the shop.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Prestige Marble & Granite INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347084246.