OSHA Inspection: NECAL CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of NECAL CORPORATION in 1326 SOUTH WATER STREET, SPARTA, WI 54656 (NAICS 325520). OSHA activity number 347084477.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Necal Corporation — free Get an email when a new federal OSHA severe-injury report for Necal Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
NECAL CORPORATION
Site address
1326 SOUTH WATER STREET
City
SPARTA
State
WI
ZIP
54656
Mailing
1326 SOUTH WATER STREET, SPARTA, WI 54656
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325520
Employees
11
Ownership type
A

7 citations on file for this inspection.

1910.146 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 12, 2024
Abate by
Apr 29, 2024
Penalty
Initial $3,134 · Current $1,410 Reduced
29 CFR  1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:  On or about January 15, 2024, the employer did not inform exposed employees, including those tasked with entering the Despatch curing oven, of the existence and location of the danger posed by the permit space.
Recent events (2)
  • — I (S) $1410
  • — Z (S) $3134

1910.146 C04

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 12, 2024
Abate by
Apr 29, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.146(c)(4):  When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:  On or about January 15, 2024, the employer did not develop and implement a written permit space entry program to protect exposed employees, including those tasked with entering the Despatch curing oven, from the dangers posed by the permit space.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 12, 2024
Abate by
Apr 29, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:   On or about January 15, 2024, the employer did not provide training so that all exposed employees, including those tasked with entering the Despatch curing oven, acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 12, 2024
Abate by
Apr 29, 2024
Penalty
Initial $3,134 · Current $1,410 Reduced
29 CFR  1910.147(f)(3)(i):  A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft:  On or about January 15, 2024, the employer did not afford exposed employees, including those tasked with entering the Despatch curing oven, a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed, including the cleaning of rollers:
Recent events (2)
  • — I (S) $1410
  • — Z (S) $3134

1910.147 C07 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 12, 2024
Abate by
Apr 29, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(A):  Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:   On or about January 15, 2024, the employer did not provide training to exposed employees, including those tasked with entering the Despatch curing oven, training in lockout and tagout  when servicing and/or maintenance was performed, including the cleaning of rollers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B11 II

Other-than-serious 1 instance 1 exposed
Issued
Apr 12, 2024
Abate by
May 3, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements.  On or about January 31, 2024, at the infeed side of Coater 3, the coater operator was not protected from falls by a stair rail system on the back-side stairs to the operators platform. These stairs have three treads and four risers and is open on both sides, and was not equipped with a stair rail system on either side of the staircase. Table D-2 requires such stairs be equipped with stair rail system on both open sides.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F06 II

Other-than-serious 1 instance 1 exposed
Issued
Apr 12, 2024
Abate by
May 3, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 0430

29 CFR  1910.1200(f)(6)(ii):  Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  On or about January 31, 2024, at the part-cleaning station in the barrel room, employees cleaning parts in 2-butanone (methyl ethyl ketone) utilized a stationary cleaning tank that was not labeled with the information necessary. The container was filled with 2-butanone, however the label affixed was illegible, and did not describe the contents of the workplace container nor the physical and health hazards of the methyl ethyl ketone, which include flammability as well as headache, dizziness, vomiting, and irritation of the eyes, skin, and nose.