Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOLCIUS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOLCIUS LLC in 303 N DREW STREET, APPLETON, WI 54911 (NAICS 238210). OSHA activity number 347085763.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Solcius LLC — free Get an email when a new federal OSHA severe-injury report for Solcius LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SOLCIUS LLC
Site address
303 N DREW STREET
City
APPLETON
State
WI
ZIP
54911
Mailing
1555 N FREEDOM BLVD, PROVO, UT 84604
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
18
Ownership type
A

2 citations on file for this inspection.

1926.453 B02 V

Serious Gravity 10 1 instance 4 exposed
Issued
Nov 28, 2023
Abate by
Dec 27, 2023
Penalty
Initial $10,938 · Current $10,938
29 CFR  1926.453(b)(2)(v):A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.  On or about November 3, 2023, at a work-site located at 303 N Drew Street Appleton, Wisconsin; employees working from a SkyJack Telescopic Boom lift (Model No.: SJ66T, Serial No.: 7060 104361) were not wearing body harnesses and lanyards, exposing those employees to potential falls of greater than 15 feet to the hard surface below.  Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e).
Recent events (1)
  • — Z (S) $10938

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 28, 2023
Abate by
Dec 27, 2023
Penalty
Initial $10,938 · Current $10,938
29 CFR  1926.501(b)(1):"Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  On or about November 3, 2023, at a work-site located at 303 N Drew Street Appleton, Wisconsin; employees were installing solar panels on the roof of a two-story Victorian-style residence without utilizing a conventional form of fall protection, exposing them to fall hazards greater than 15 feet to the hard surface below.