Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TAP BUILDERS, LLC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TAP BUILDERS, LLC. in 10506 WISCONSIN AVE., HAYWARD, WI 54843 (NAICS 238130). OSHA activity number 347089278.

Watch TAP Builders, LLC. — free Get an email when a new federal OSHA severe-injury report for TAP Builders, LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
TAP BUILDERS, LLC.
Site address
10506 WISCONSIN AVE.
City
HAYWARD
State
WI
ZIP
54843
Mailing
14043 WEST PETERSON ROAD, HAYWARD, WI 54843
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

4 citations on file for this inspection.

1903.19 C01

Other-than-serious 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $388.00 · Current $388.00
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  (a) Citation 1, Item 1a; a serious violation of 29 CFR 1926.451(b)(5)(ii) with an abatement date of February 2, 2024.  (b) Citation 1, Item 1b; a serious violation of 29 CFR 1926.451(f)(7) with an abatement date of February 2, 2024.  (c) Citation 1, Item 1c; a serious violation of 29 CFR 1926.451(g)(1)(i) with an abatement date of February 2, 2024.
Recent events (1)
  • — Z (O) $388

1926.451 B05 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2679.00 · Current $2679.00
29 CFR  1926.451(b)(5)(ii):The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end:  (a) A scaffold stage greater than 10 feet in length, used as a work platform of a ladder jack scaffold system to sheath a roof, extended more than 18 inches over the bracket supports. The cantilevered end(s) were not properly supported and were not equipped with guardrails.
Recent events (1)
  • — Z (S) $2679

1926.451 F07

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:   (a) Employees utilized a scaffold stage as part of a ladder jack scaffold system work platform to sheath a roof and it extended more than 18 inches over the bracket supports, the cantilevered end(s) were not properly supported and were not equipped with guardrails, and no fall protection was utilized.  A competent person was not involved.
Recent events (1)
  • — Z (S) $0

1926.451 G01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system when working at heights greater than 10 feet:  (a) Employee(s) were working from a ladder jack scaffold platform approximately 16-20 feet above ground level without the use of fall protection.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347089278.