MCFARLAND, WI —
OSHA Inspection: EMERALD BLUE WORKSPACE SERVICES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EMERALD BLUE WORKSPACE SERVICES in 4760 MCFARLAND COURT, MCFARLAND, WI 53558 (NAICS 423210). OSHA activity number 347095432.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EMERALD BLUE WORKSPACE SERVICES
- Site address
- 4760 MCFARLAND COURT
- City
- MCFARLAND
- State
- WI
- ZIP
- 53558
- Mailing
- 4760 MCFARLAND COURT, MCFARLAND, WI 53558
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423210
- Employees
- 27
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.178 A04
- Issued
- Apr 23, 2024
- Abate by
- May 1, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: On or about November 8, 2023, a Crown 30SCTT Forklift (S/N 1A127733) was being used in the warehouse area which exposed employees to powered industrial trucks with fork lift extenders that can affect the safe capacity and safe operation while working in the warehouse area.
Recent events (1)
- — Z (O) $0
1910.178 A05
- Issued
- Apr 23, 2024
- Abate by
- May 1, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(5) :The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: On or about November 8, 2023, a Crown 30SCTT Forklift (S/N 1A127733) was not properly marked to identify the fork lift extenders showing the maximum elevation with load laterally centered.
Recent events (1)