ORLANDO, FL —
OSHA Inspection: RODRIGUEZ G CONSTRUCTION INC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of RODRIGUEZ G CONSTRUCTION INC in 8165 ELION STREET, ORLANDO, FL 32827 (NAICS 236115). OSHA activity number 347097990.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RODRIGUEZ G CONSTRUCTION INC
- Site address
- 8165 ELION STREET
- City
- ORLANDO
- State
- FL
- ZIP
- 32827
- Mailing
- 33 EAST ROBINSON STREET, STE 109, ORLANDO, FL 32801
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 F14
- Issued
- Dec 11, 2023
- Penalty
- Initial $3,349 · Current $3,349
General-duty citation text
29 CFR 1926.451(f)(14): Makeshift devices, such as boxes and barrels were used on top of scaffold platforms to increase the working level height of employees. a) On or about October 11, 2023: at the front and left side of the building, employees were exposed to 15 feet 9-inch to 16 feet 4-inch fall hazards while using an unstable tubular welded scaffold to conduct stucco repair. Employees used multiple plastic buckets to raise the scaffold height on tier 3 of the platform.
Recent events (1)
- — Z (S) $3349
1926.451 E01
- Issued
- Dec 11, 2023
- Penalty
- Initial $3,349 · Current $3,349
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. The scaffold structure was used as a means of access. a) On or about October 11, 2023; at the front and the left side of the building, employees were exposed to a 15 feet 9 inch to 16 feet 3 inch fall hazards, in that, employees were climbing the scaffold frame and were not provided a safe means of access to upper levels of the scaffold.
Recent events (1)
- — Z (S) $3349
1926.451 F03
- Issued
- Dec 11, 2023
- Abate by
- Jan 8, 2024
- Penalty
- Initial $3,349 · Current $3,349
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) On or about October 11, 2023: at the front and left side of the building, employees were exposed to a 15 feet 9 inch to 16 feet 3 inch fall hazards, in that, the scaffold was not checked by a competent person for defects prior to use.
Recent events (1)
- — Z (S) $3349
1926.451 F07
- Issued
- Dec 11, 2023
- Abate by
- Jan 8, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7):Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a) On or about October 11, 2023: at the front and left side of the building, employees were exposed to a 15 feet 9 inch to 16 feet 3 inch fall hazard, in that, the scaffold was not erected under the supervision of a competent person.
Recent events (1)
- — Z (S) $0
1926.451 G01
- Issued
- Dec 11, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about October 11, 2023; at the site, employees performing stucco repair at the front of the building were not provided with guardrail or fall protection, exposing them to fall hazards of 15 feet 9 inches up to 16 feet 3 inches.
Recent events (1)
- — Z (S) $4688
More inspections at Rodriguez G Construction INC
View Rodriguez G Construction INC's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347097990.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.